DistillColumnLab
Menu

Worked example · Reaction engineering

Many CSTRs approximate plug flow

Compare ideal reactor volumes, space time and equal-tank conversion for zero-, first- or second-order kinetics.

Divide the volume across 40 equal CSTRs and compare total cascade size against a PFR.

CSTR volume
20.57 m³
PFR volume
9.506 m³
CSTR / PFR
2.164
Cascade X
74.41 %

Levenspiel volume comparison

Live schematic
Levenspiel plot of PFR area under the rate curve and the CSTR rectangle00.170.340.50.670.8407.7152331Fₐ₀ / (−rₐ) · m³CONVERSION XPFR areaCSTR rectangleCascade check
PFR-sized cascade falls short

The conversion check holds total cascade volume at the PFR volume. Use the separate cascade size to meet the target.

PFR-sized cascade conversion vs target74.4 %
Near target 74.6 % Target 75 %

Worked solution

  1. Evaluate the rate at temperature

    The Arrhenius correction gives k = 1.05 h⁻¹. At X = 75 %, CA = 0.3125 kmol/m³.

  2. Compare the Levenspiel areas

    The outlet-rate rectangle gives 20.57 m³. Integrating through the concentration change gives 9.506 m³. The single-tank penalty is 2.164 times.

  3. Check the cascade

    40 equal tanks at PFR total volume reach 74.41 %. At the target, the cascade requires 9.673 m³ total.

Reducing the concentration jump between tanks brings total volume closer to the plug-flow limit. The derivation uses SI units.

Calculation details
Operating rate constant1.05 h⁻¹
Total cascade volume at target9.673 m³
Volume per equal tank0.2418 m³
CSTR space time2.857 h
PFR space time1.32 h
Cascade space time at target1.343 h
Outlet concentration CA0.3125 kmol/m³
PFR-sized cascade shortfall0.594 pp

Calculation inputs

Live updates

Kinetics
h⁻¹
°C
°C
kJ/mol
0 disables temperature correction
Feed and design target
m³/h
kmol/m³
%
Back to results

Equations and assumptions

Power-law kinetics
−rA = k · CA^n
Temperature adjustment
k = kref exp[(Ea/R)(1/Tref − 1/T)]
Single CSTR
VCSTR = FA₀X / [k CA₀^n (1 − X)^n]
Plug flow
VPFR = ∫₀ˣ FA₀ / (−rA) dX

The ideal model is steady state, isothermal and constant density. It assumes one irreversible power-law reaction and no change in volumetric flow. Enter a rate constant with units for the selected order.

The cascade check divides the PFR volume among equal CSTRs. A separate cascade sizing step computes the volume needed at the target. For second order each tank solves Ci + kτtank Ci² = Ci−1 using a cancellation-safe positive root.

Method references