Worked example
Weight per length 3.19 lb/ft
- Subtract the area of the 1.750 in inner square from the 2.000 in outer square. The sharp-corner section has 0.9375 in² of metal.
- Apply density and convert to pounds per foot. Multiply by 24 ft per stick and three sticks for the order total.
Before using this result. Compare to the exact HSS table or supplier mass per foot because corner radii and design thickness may change area.
Formulas and assumptions
- Mass = cross-section area × length × density
- Calculate a theoretical piece weight, then multiply by quantity for batch weight and by your price per unit weight for cost.
- Tube area = outer area − hollow area
- Rectangular tube uses (w − 2t)(h − 2t) for the hollow. Round tube uses an inner diameter of D − 2t.
- Angle area = t(w + h − t)
- Sum both legs and subtract the overlapping corner. Beam and channel area use two full flanges plus the web between them.
Engineering references
Frequently asked questions
Can I use the structural design wall in this 2×2 weight estimate?
Use the measured or supplier wall for mass. A code design wall may be reduced for strength calculations and can differ from actual material.
What does the tube size use for the outside dimension?
The 2×2 is measured across its outside faces. Subtract two wall thicknesses from each side length to find the inner square.