Worked example
Weight per length 3.694 lb/ft
- Start with the published 2.375 in OD rather than the nominal 2 in size. Subtract two 0.154 in walls to get a 2.067 in ID.
- Subtract inner circle area from outer area. Apply 304 density to get dry weight per foot, then multiply by the 10 ft length.
Before using this result. Verify the stainless schedule and stock density against your supplier. Include contents, insulation and fittings when estimating installed load.
Formulas and assumptions
- Mass = cross-section area × length × density
- Calculate a theoretical piece weight, then multiply by quantity for batch weight and by your price per unit weight for cost.
- Tube area = outer area − hollow area
- Rectangular tube uses (w − 2t)(h − 2t) for the hollow. Round tube uses an inner diameter of D − 2t.
- Angle area = t(w + h − t)
- Sum both legs and subtract the overlapping corner. Beam and channel area use two full flanges plus the web between them.
Engineering references
Frequently asked questions
Should I use 2.000 in OD for this Schedule 40S material takeoff?
Use 2.375 in for NPS 2. The nominal dimension names the size family and does not equal the measured outside diameter.
How do I estimate the weight of water inside this pipe?
Use the calculated inside diameter and length to find the cylindrical liquid volume. Multiply that volume by water density at the intended temperature.