Worked example

Estimated working pressure 2,190 psi

  1. Apply the negative wall tolerance to 0.438 in nominal wall. The resulting 0.38325 in effective wall is more than 10% of 3.500 in OD.
  2. The displayed comparison still uses Barlow’s equation. For engineering design, check through-wall stresses and the method required by the applicable code.

Before using this result. Use an appropriate thick-wall analysis, confirmed material, service temperature and the qualified pipe assembly’s actual ratings.

Formulas and assumptions

tₑ = tnom (1 − wall tolerance) − wall loss
Apply the tolerance as a fraction. Enter a verified minimum wall and a zero tolerance when working with inspected pipe.
P = 2Stₑ / Dₒ
Barlow’s equation uses the outside diameter. Use tensile strength for theoretical burst and yield strength for first-yield pressure.
Pworking = Pyield / SF
The selected yield factor is a worksheet assumption. Hoop stress at an entered pressure is PDₒ / (2tₑ).

Engineering references

Frequently asked questions

What makes the thick-wall reminder appear in this Schedule 160 case?

The effective wall divided by the outside diameter exceeds 0.10. Hoop stress varies through a thick wall.

How does the safety factor affect this thick-wall estimate?

A higher factor reduces the reported working estimate. The thick-wall reminder depends on the effective wall-to-OD ratio.