Worked example
Estimated working pressure 2,190 psi
- Apply the negative wall tolerance to 0.438 in nominal wall. The resulting 0.38325 in effective wall is more than 10% of 3.500 in OD.
- The displayed comparison still uses Barlow’s equation. For engineering design, check through-wall stresses and the method required by the applicable code.
Before using this result. Use an appropriate thick-wall analysis, confirmed material, service temperature and the qualified pipe assembly’s actual ratings.
Formulas and assumptions
- tₑ = tnom (1 − wall tolerance) − wall loss
- Apply the tolerance as a fraction. Enter a verified minimum wall and a zero tolerance when working with inspected pipe.
- P = 2Stₑ / Dₒ
- Barlow’s equation uses the outside diameter. Use tensile strength for theoretical burst and yield strength for first-yield pressure.
- Pworking = Pyield / SF
- The selected yield factor is a worksheet assumption. Hoop stress at an entered pressure is PDₒ / (2tₑ).
Engineering references
Frequently asked questions
What makes the thick-wall reminder appear in this Schedule 160 case?
The effective wall divided by the outside diameter exceeds 0.10. Hoop stress varies through a thick wall.
How does the safety factor affect this thick-wall estimate?
A higher factor reduces the reported working estimate. The thick-wall reminder depends on the effective wall-to-OD ratio.