Worked example
Estimated working pressure 205.71 psi
- Use actual tube OD and a sample verified minimum wall of 0.045 in. Since this example enters an assumed measured minimum, set further mill tolerance to 0.
- Apply the illustrative 6 ksi yield stress for annealed C12200 and the selected yield factor of 3. Compare separately with published tube and joining-system ratings.
Before using this result. Use the Copper Tube Handbook or supplier ratings for the actual temper, temperature, joining process and governing code.
Formulas and assumptions
- tₑ = tnom (1 − wall tolerance) − wall loss
- Apply the tolerance as a fraction. Enter a verified minimum wall and a zero tolerance when working with inspected pipe.
- P = 2Stₑ / Dₒ
- Barlow’s equation uses the outside diameter. Use tensile strength for theoretical burst and yield strength for first-yield pressure.
- Pworking = Pyield / SF
- The selected yield factor is a worksheet assumption. Hoop stress at an entered pressure is PDₒ / (2tₑ).
Engineering references
Frequently asked questions
Does 3/4 in Type L copper use the steel NPS schedule table?
Copper water tube follows its own type and nominal size scheme. Enter the actual 0.875 in OD and product wall.
How can brazing affect the copper pressure rating?
Heat can soften hard-drawn copper locally. Check the joining-system rating and the applicable annealed-tube criteria.