Worked example

Retraction pull force 9,189.16 lbf

  1. The bore area is 25π/4 in² and the annulus is 4π in². Push and pull use opposite sides for supply and return.
  2. For pull subtract 300 psi times 25π/4 in² from 1,200 psi times 4π in². Try changing return pressure to 0 to see the ideal upper estimate.

Before using this result. Confirm that the readings come from the cylinder ports in the relevant motion direction. A directional valve can change return pressure between extend and retract.

Formulas and assumptions

Aᴄ = πD²/4 and Aᵣ = π(D² − d²)/4
D is bore diameter and d is rod diameter. The rod displaces part of the working area during retraction.
Fpush = Pₛ Aᴄ − Pᵣ Aᵣ
For pull force use Pₛ Aᵣ − Pᵣ Aᴄ. With MPa and mm², the result is newtons.
Speed = flow ÷ area and target flow = speed × area
Divide stroke by speed to estimate stroke time. The formulas assume cylinder inlet flow remains constant throughout the stroke.
Hydraulic hp ≈ PSI × GPM / 1,714
Use supply gauge pressure relative to the pump inlet. Divide fluid power by the overall pump efficiency for estimated shaft power.

Engineering references

Frequently asked questions

How much pull is lost for each additional psi of return pressure here?

The 5 in piston has about 19.63 in² of cap area. Each extra psi on that side removes about 19.63 lbf from the model’s pull.

Can a larger rod make return pressure more significant?

Yes. Increasing rod size reduces supply-side annulus force during pull while the opposing cap area remains the same.