Preliminary estimate. Forces are static estimates with the stated pressures at the cylinder. Verify component ratings, rod buckling, mounting, end cushioning, relief settings and the flow available under load before sizing a circuit.
Formulas and assumptions
Aᴄ = πD²/4 and Aᵣ = π(D² − d²)/4
D is bore diameter and d is rod diameter. The rod displaces part of the working area during retraction.
Fpush = Pₛ Aᴄ − Pᵣ Aᵣ
For pull force use Pₛ Aᵣ − Pᵣ Aᴄ. With MPa and mm², the result is newtons.
Speed = flow ÷ area and target flow = speed × area
Divide stroke by speed to estimate stroke time. The formulas assume cylinder inlet flow remains constant throughout the stroke.
Hydraulic hp ≈ PSI × GPM / 1,714
Use supply gauge pressure relative to the pump inlet. Divide fluid power by the overall pump efficiency for estimated shaft power.
Why does the rod retract faster than it extends at the same flow?
A given oil volume moves the piston farther on the rod side because the rod reduces the effective area.
Where should I measure hydraulic pressure for force calculations?
Measure at both cylinder ports under the intended load. The return-side pressure can be material when flow passes through valves, hoses or restrictions.