Worked example

Air-bend force per length 4.13 US tonf/ft

  1. Set the 1.000 in V-opening with a measured 0.125 in sheet. The opening-to-thickness ratio is 8. Load 31 ksi as an example tensile strength for this temper.
  2. Compute 1.42 Rₘt²/V in metric units to get line force. The 36 in bend uses three feet of tooling, so total US ton-force is three times the force per foot.

Before using this result. Verify the 5052 temper, purchase certificate and minimum flange support. Use the press and tool load charts for the actual setup.

Formulas and assumptions

BA = θ (R + Kt)
Use radians for θ, the angle swept from flat. R is the inside radius and t is the actual stock thickness. K is the neutral-axis offset as a fraction of thickness.
OSSB = (R + t) tan(θ/2)
Outside setback is measured along the flange from the virtual outside corner to its tangent point.
BD = 2 OSSB − BA
Subtract one bend deduction from the sum of the two outside flange dimensions to get the blank length.
F/L ≈ 1.42 Rₘt²/V
Use Rₘ in MPa and t and V in mm for kN/m. Multiply by the bend length in meters for total kN. 1 US ton-force equals 2,000 lbf.

Engineering references

Frequently asked questions

What happens to this force estimate if I change to a 3/4 in die?

With the same material, thickness and length, the force rises in inverse proportion to die width, by about one third. The actual inside radius will likely change too.

Why specify H32 for the 5052 example?

Temper affects tensile strength and formability. Enter the strength of the supplied stock when comparing to another 5052 temper.