Preliminary estimate. The 6–8× V-opening range is a starting point for thin mild steel. The tool, surface condition, strain hardening, grain direction and springback can change the result. Measure a test bend and check the press brake and tooling load charts.
Formulas and assumptions
BA = θ (R + Kt)
Use radians for θ, the angle swept from flat. R is the inside radius and t is the actual stock thickness. K is the neutral-axis offset as a fraction of thickness.
OSSB = (R + t) tan(θ/2)
Outside setback is measured along the flange from the virtual outside corner to its tangent point.
BD = 2 OSSB − BA
Subtract one bend deduction from the sum of the two outside flange dimensions to get the blank length.
F/L ≈ 1.42 Rₘt²/V
Use Rₘ in MPa and t and V in mm for kN/m. Multiply by the bend length in meters for total kN. 1 US ton-force equals 2,000 lbf.
How does the bend angle differ from the included angle?
The bend angle is measured from flat. For an included angle of 120°, enter a bend angle of 60°.
Can I add deductions for several bends in one blank?
For distinct bends laid out with outside dimensions to each virtual corner, sum the applicable deductions. Use the angle, radius and thickness for each bend.