Worked example · Dimensional capability
Plate thickness and the Taguchi target
Compare Cpk and Cpm for a plate whose functional 1.47 mm target sits below the specification midpoint.
Cpk = min(Cpu, Cpl)
Baseline reading
The mean is 0.07 mm above target. Cpm includes both the 0.02 mm spread and the 0.07 mm distance to the functional target.
What to test
Model the target shift only if downstream forming accepts it. Compare both capability and performance at the intended nominal.
Worksheet inputs
Inputs
Results
- Cpk · nearest specification limit
- 0.66667
- Cp · potential capability
- 1.33333
- Cpu · upper capability
- 0.66667
- Cpl · lower capability
- 2
- Cpm · Taguchi index
- 0.36629
- Ppk · overall capability
- —
- Pp · overall spread index
- —
- Off-center shift
- 50%
- Expected out-of-spec PPM
- 22,750.13293
- Below-LSL PPM
- 0.00099
- Above-USL PPM
- 22,750.13195
Model notes
Use a within-process sigma for Cp, Cpk and the tail prediction. Supply a separate overall sigma for Pp and Ppk based on the longer observation window.
Check the measurement system and process stability before using the normal tail model. The two shaded tails represent predicted proportions outside the drawing limits.
Frequently asked questions
Can a plate meet drawing limits while missing the design target?
Yes. The drawing permits a range, and the functional target may sit inside it. Cpm penalizes departure from that target.
What happens to Cpm if the plate coil variance falls but the mean stays high?
It improves, while the remaining target offset still constrains the index. Check centering and dispersion as separate actions.