FactoryOEELab

Worked example · Defects and yield

Powder coating estimated first-pass yield

Estimate first-pass powder coating yield when the shift records appearance defects without a distinct failed-part count.

DPMO = Defects ÷ Opportunities × 1,000,000

Baseline reading

The worksheet uses the Poisson zero-defect probability exp(−41 ÷ 1,500) for an estimated first-pass yield.

What to test

Tag affected part IDs next shift. Clustering of adhesion or appearance defects on the same part can make the estimated unit yield differ from the tally.

Currency labels entered amounts. Exports record the selected display units.

Inputs

Inspection tally

Enter the actual failed-unit count for measured FPY.

Step first-pass yields
%
%
%
%
%
%

Results

Defects per million opportunities
5,466.66667
Normal-equivalent sigma level
4.04482σ
Defects per unit
0.02733

First-pass unit yield is a Poisson estimate. Enter the failed-unit count for a measured result.

Defect rate and sigma benchmark
Defect rate and sigma benchmark Observed defects per million opportunities on a logarithmic scale, with the equivalent sigma at the reference marks. DPMO / LOG SCALE+1.5σ convention0.00017.9σ0.017.1σ16.3σ1005.2σ10K3.8σ1M—5.5K DPMO
Opportunity yield
99.4533%
First-pass unit yield
97.3037%
Rolled throughput yield
—
Total defect opportunities
7,500

Model notes

Measure first-pass unit yield with the number of units that failed at least once. If that tally is blank, the worksheet estimates unit yield as exp(−DPU) under a Poisson model.

The 1.5σ option adds a reporting convention to a one-sided normal equivalent. Use consistent opportunity definitions when comparing processes.

View the equations

Frequently asked questions

Why could coating defects cluster on selected panels?

Grounding, film thickness, contamination, and oven position can affect more than one characteristic on the same panel. Check the counted failed panels before assuming independent opportunities.

What improves the powder-coat FPY estimate most directly?

Record the number of unique panels that fail the first pass. Enter that figure and use the measured result.