Worked example · Dimensional capability
Seal thickness in millimeters and inches
Switch a seal flange from millimeters to inches and compare unchanged Cpk and predicted defect tails.
Cpk = min(Cpu, Cpl)
Baseline reading
The upper wall is 0.035 mm from the mean, so upper capability controls. The missing target leaves the Taguchi index unavailable.
What to test
Switch the dimension selector to inches before answering the customer drawing. Keep unrounded readings in the original inspection record.
Worksheet inputs
Inputs
Results
- Cpk · nearest specification limit
- 0.83333
- Cp · potential capability
- 0.95238
- Cpu · upper capability
- 0.83333
- Cpl · lower capability
- 1.07143
- Cpm · Taguchi index
- —
- Ppk · overall capability
- —
- Pp · overall spread index
- —
- Off-center shift
- 12.5%
- Expected out-of-spec PPM
- 6,863.51273
- Below-LSL PPM
- 653.8474
- Above-USL PPM
- 6,209.66533
Model notes
Use a within-process sigma for Cp, Cpk and the tail prediction. Supply a separate overall sigma for Pp and Ppk based on the longer observation window.
Check the measurement system and process stability before using the normal tail model. The two shaded tails represent predicted proportions outside the drawing limits.
Frequently asked questions
Should a seal capability index change when mm becomes inches?
All means, limits, and deviations scale by the same factor, so the capability ratios and normal tail estimates are invariant.
Can I use the seal drawing midpoint as its Taguchi target?
Use a midpoint only if engineering confirms it is the desired functional value. Leave the target blank when the drawing specifies only limits.