Home Spray calibration
Worked example Calibrating a 60-Foot Boom at 15 GPA Find per-tip output at 6 mph with 20-inch nozzle centers and 15 GPA, then plan the final tank for 85 acres.
The product label is the law
The product label is the law. Calibrate with clean water. Check directions, site, nozzle limits, drift controls and personal protective equipment on the legally governing label.
Chemical, herbicide and pesticide product labels are legally governing. Follow the registered label and applicable local law. Grain moisture shrink factors and drying fees vary by buyer and elevator schedule. Certified soil-lab recommendations govern lime and fertilizer applications. Actual machine field efficiency varies with terrain, field shape and crop conditions.
{"tool":"sprayer","preset":{"mode":"target","speed":6,"spacing":20,"rate":15,"catch":38.8,"boom":60,"tank":500,"acres":85,"product":0,"pressure":40},"unitSystem":"us","route":"/examples/calibrate-60-foot-boom-15-gpa/","fileName":"calibrate-60-foot-boom-15-gpa"}
Planning estimate
Flow per nozzle
0.303 US gpm
Carrier application rate
15 GPA
Area per full tank
33.33 ac
Product per full tank
0 fl oz
Carrier in final partial tank
275 US gal
Product for final partial tank
0 fl oz
Area left for partial tank
18.33 ac
Full tanks for this field
2
Approximate nozzles across swath
36 nozzles
Estimated total boom flow
10.91 US gpm
Rate at 20% faster and fixed pressure
12.5 GPA
Pressure at 20% faster for same rate
57.6 psi
Boom spacing & speed response
Boom spacing & speed response Operating swath 20 in nozzle centers 36 tips estimated GPA at fixed pressure 4.2 mph 7.8 mph Current rate 15 GPA · 20% faster 12.5 GPA
Share link
Print / PDF
JSON
CSV
SVG
Link format Query string Private fragment
Worksheet link
Copy link
Field note Use the nozzle output as the starting point for a clean-water catch. Confirm field speed under load and use the nozzle’s approved operating range.
Questions from the field
What does the 60-foot swath imply for 20-inch nozzle centers? The entered effective width contains 720 inches. Dividing by 20 inches gives approximately 36 operating tips.
How much field does a 500-gallon tank cover at 15 GPA? A full usable 500-gallon tank covers approximately 33.33 acres at that carrier rate.