Oats Storage in a Small 21-Foot Bin

Budget oat bin space and truck payload using a 32 lb nominal bushel and a measured bulk density 10% below that reference.

Net dry marketable grain 3,350.4 bu
All results

Worksheet inputs

Bin dimensions
Measure the cylindrical grain column.
Use 0° for level grain. A peaked pile is often modeled at 28–30°.
Enter 1 for the standard volume estimate. Use a measured or published multiplier for incoming weight relative to the nominal crop weight.
Crop & delivery terms
Percentage of incoming weight under this model.
Per incoming bushel per percentage point removed.

Planning estimate

Net dry marketable grain
3,350.4 bu
Estimated incoming grain
3,396.2 bu
Geometric capacity (Winchester)
3,773.6 bu
Grain after water shrink
3,357.2 bu
Water shrink
39 bu
Handling shrink
6.8 bu
Combined shrink
1.35 %
Estimated incoming mass
49.3 t
Estimated marketable mass
48.63 t
Filled volume
4,696.1 ft³
Moisture removed
1 points
Estimated drying cost
$108.68
Bin section & bushel balance
Bin section & bushel balance21 ft diameterFilled bin4,696.1 ft³Marketable after shrink3,350.4 buMarketableWater shrinkHandling

Field note

The 0.90 factor represents an observed incoming weight of 28.8 lb per geometric bushel against the 32 lb reference. Use the scale ticket for the actual truck payload.

Questions from the field

Why are estimated incoming bushels lower than geometric capacity?

The same physical volume carries 10% less mass than the nominal oat reference. The worksheet adjusts incoming bushels before applying water and handling shrink.

Do lightweight oats change the calculated bin volume?

Physical volume comes from the measured bin and fill shape. Grain density affects the mass carried in that same volume.