120 km SMF with a DCM requirement

Extend the same 1550 nm span to 120 km and check how much negative compensation is required.

Inputs

Use the actual rate per lane. Choose a transceiver CD tolerance or estimate it from optical width and an allowed fraction of a unit interval.

Fiber and signals
km
ps/(nm·km)
ps/√km
Dispersion limits
ps/nm
nm
% UI
LIVE ANATOMY

Dispersion versus distance

Dispersion versus distanceSIGNED CD2,040ps/nmPMD / DGD1.095psMAX REACH94.118kmMIN DCM-440ps/nm|CD| / limit100% limitDGD / limit0Span 120 km144 kmDISPERSION LIMIT USE0%100% limitCD 127.5%
Dispersion limit exceededOne or both entered dispersion limits are exceeded.

Dispersion and time

Accumulated chromatic dispersion
2,040 ps/nm
CD pulse spread estimate
204 ps
DGD / PMD estimate
1.095 ps
Unit interval
100 ps
CD tolerance
1,600 ps/nm
DGD tolerance
10 ps

Reach and compensation

Combined dispersion-limited reach
94.118 km
Chromatic reach
94.118 km
PMD reach
10,000 km
Minimum signed DCM
-440 ps/nm
DCM for zero residual CD
-2,040 ps/nm

What to check

The minimum signed DCM reaches the tolerance boundary. Full compensation brings accumulated CD to zero in this model.

Open the general chromatic dispersion calculator

Formulas and assumptions

Chromatic dispersion

CD = D × L; pulse spread ≈ |CD| × Δλ

The signed D coefficient is assumed constant for the entered band. The pulse spread is a first-order narrowband estimate.

PMD and reach

DGD ≈ PMDcoef × √L; LPMD = (DGDtolerance / PMDcoef)²

A unit interval is 1000 / rate in ps when the rate is in Gbit/s for this binary signaling screen. PMD is statistical. The lower of the finite PMD and CD reach limits governs this estimate.

Compensation

DCMmin = −sign(CD) × max(0, |CD| − CDtolerance)

The minimum compensator brings dispersion to the tolerance boundary. Full compensation is −CD. Check optical loss, dispersion slope and the transceiver’s sign-dependent limits before specifying a DCM.

The G.652.D example uses a representative 17 ps/(nm·km) at 1550 nm. G.655 shifts dispersion to a nonzero value in that band, represented here by an editable +4. Use equipment-specific tolerance and PMD outage limits for coherent, PAM4 and other nonbinary links.

Worked examples

Open a scenario and edit any parameter.