100G lane limited by PMD

Near-zero CD and elevated PMD shift the bottleneck to differential group delay.

Inputs

Use the actual rate per lane. Choose a transceiver CD tolerance or estimate it from optical width and an allowed fraction of a unit interval.

Fiber and signals
km
ps/(nm·km)
ps/√km
Dispersion limits
ps/nm
nm
% UI
LIVE ANATOMY

Dispersion versus distance

Dispersion versus distanceSIGNED CD0ps/nmPMD / DGD2.5psMAX REACH4kmMIN DCM0ps/nm|CD| / limit100% limitDGD / limit0Span 25 km30 kmDISPERSION LIMIT USE0%100% limitPMD 250%
Dispersion limit exceededOne or both entered dispersion limits are exceeded.

Dispersion and time

Accumulated chromatic dispersion
0 ps/nm
CD pulse spread estimate
0 ps
DGD / PMD estimate
2.5 ps
Unit interval
10 ps
CD tolerance
1,600 ps/nm
DGD tolerance
1 ps

Reach and compensation

Combined dispersion-limited reach
4 km
Chromatic reach
Unbounded in model
PMD reach
4 km
Minimum signed DCM
0 ps/nm
DCM for zero residual CD
0 ps/nm

What to check

With D set to zero, a finite PMD limit still bounds usable reach.

Open the general chromatic dispersion calculator

Formulas and assumptions

Chromatic dispersion

CD = D × L; pulse spread ≈ |CD| × Δλ

The signed D coefficient is assumed constant for the entered band. The pulse spread is a first-order narrowband estimate.

PMD and reach

DGD ≈ PMDcoef × √L; LPMD = (DGDtolerance / PMDcoef)²

A unit interval is 1000 / rate in ps when the rate is in Gbit/s for this binary signaling screen. PMD is statistical. The lower of the finite PMD and CD reach limits governs this estimate.

Compensation

DCMmin = −sign(CD) × max(0, |CD| − CDtolerance)

The minimum compensator brings dispersion to the tolerance boundary. Full compensation is −CD. Check optical loss, dispersion slope and the transceiver’s sign-dependent limits before specifying a DCM.

The G.652.D example uses a representative 17 ps/(nm·km) at 1550 nm. G.655 shifts dispersion to a nonzero value in that band, represented here by an editable +4. Use equipment-specific tolerance and PMD outage limits for coherent, PAM4 and other nonbinary links.

Worked examples

Open a scenario and edit any parameter.