Power conversion
P(mW) = 10^(dBm / 10); dBm = 10 log₁₀(PmW); P(µW) = 1000 × P(mW)
Enter positive linear power. Equal-power WDM channels sum in linear units.
An 80-line plan at −1 dBm per line exceeds a 17 dBm EDFA output limit.
EDFA output limit exceeded by 1.031 dB. Verify composite saturation headroom at the entered output plane.
Composite power is at or above +10 dBm. Review the accessible optical power and marked laser class.
Class 3B equipment: direct beam exposure is hazardous.
The EDFA limit is checked on the composite at the amplifier output plane.
Open the general optical power converter calculatorP(mW) = 10^(dBm / 10); dBm = 10 log₁₀(PmW); P(µW) = 1000 × P(mW)
Enter positive linear power. Equal-power WDM channels sum in linear units.
Ptotal(dBm) = Pchannel + 10 log₁₀(N); headroom = EDFA limit − Ptotal
Use a per-channel level at the EDFA output plane for this comparison. Check the manufacturer’s gain, ASE, channel loading and saturation limits.
RXtarget = (sensitivity + overload ceiling) / 2; Acenter = max(0, RX − RXtarget)
The midpoint in dBm leaves equal dB headroom on either side. An attenuator can lower power only. Use the correct receiver plane and rated component.
Laser class comes from the equipment marking and applicable accessible emission limits. A separate +10 dBm composite advisory highlights elevated optical power for review. IEC Class 1M and Class 3B handling depends on the marked class and accessible emission conditions.
Open a scenario and edit any parameter.
FiberOpticLab
Within RX window. Received power lies within the entered receiver window.
EDFA output limit exceeded by 1.031 dB. Verify composite saturation headroom at the entered output plane.
Composite power is at or above +10 dBm. Review the accessible optical power and marked laser class.
Class 3B equipment: direct beam exposure is hazardous.
Follow IEC 60825-2 and ANSI Z136.2 procedures. Never inspect an energized fiber or connector with your eye or an optical magnifier. Verify the installed link with a calibrated power meter and field OTDR at the relevant wavelengths, using appropriate launch and receive fibers and a safe test setup.
Correct the inputs to print an engineering report.