Inline attenuator for RX overload

A 3 dBm launch and 2 dB of plant loss put the receiver above its −7 dBm ceiling.

Inputs

Edit any power unit to update the other two. Select aggregate RX only when the receiver’s limits apply to the entire optical band.

Optical power and channels
Power per channel
dBm
Receiver and attenuation
dB
dBm
dBm
LIVE ANATOMY

Receiver dynamic range

Receiver dynamic rangeCOMPOSITE3dBmRX INPUT1dBmCENTER ATTEN16dBEDFA ROOM17dBInput 1 dBmAfter pad -15 dBmRX floor-23 dBmMidpoint-15 dBmRX ceiling-7 dBmRECEIVER WINDOWRX floorRX ceiling1 dBm input
Attenuator neededReceived power exceeds the ceiling. Check the minimum and midpoint attenuation.

Class 1M equipment: viewing through collecting optics may be hazardous.

Power and amplifier

Per-channel optical power
3 dBm
Per-channel linear power
1.995262 mW
Per-channel linear power
1,995.262315 µW
Composite optical power
3 dBm
Composite linear power
1.995262 mW
EDFA headroom
17 dB

Receiver and attenuator

RX before attenuation
1 dBm
Window midpoint
-15 dBm
Minimum to clear overload
8 dB
Attenuation to midpoint
16 dB
Maximum before sensitivity
24 dB
RX after calculated attenuation
-15 dBm

What to check

Compare the smallest attenuator that clears overload with the value that centers the receive level.

Open the general optical power converter calculator

Formulas and assumptions

Power conversion

P(mW) = 10^(dBm / 10); dBm = 10 log₁₀(PmW); P(µW) = 1000 × P(mW)

Enter positive linear power. Equal-power WDM channels sum in linear units.

Composite power and EDFA headroom

Ptotal(dBm) = Pchannel + 10 log₁₀(N); headroom = EDFA limit − Ptotal

Use a per-channel level at the EDFA output plane for this comparison. Check the manufacturer’s gain, ASE, channel loading and saturation limits.

Inline attenuation

RXtarget = (sensitivity + overload ceiling) / 2; Acenter = max(0, RX − RXtarget)

The midpoint in dBm leaves equal dB headroom on either side. An attenuator can lower power only. Use the correct receiver plane and rated component.

Laser class comes from the equipment marking and applicable accessible emission limits. A separate +10 dBm composite advisory highlights elevated optical power for review. IEC Class 1M and Class 3B handling depends on the marked class and accessible emission conditions.

Worked examples

Open a scenario and edit any parameter.