Power conversion
P(mW) = 10^(dBm / 10); dBm = 10 log₁₀(PmW); P(µW) = 1000 × P(mW)
Enter positive linear power. Equal-power WDM channels sum in linear units.
A 3 dBm launch and 2 dB of plant loss put the receiver above its −7 dBm ceiling.
Class 1M equipment: viewing through collecting optics may be hazardous.
Compare the smallest attenuator that clears overload with the value that centers the receive level.
Open the general optical power converter calculatorP(mW) = 10^(dBm / 10); dBm = 10 log₁₀(PmW); P(µW) = 1000 × P(mW)
Enter positive linear power. Equal-power WDM channels sum in linear units.
Ptotal(dBm) = Pchannel + 10 log₁₀(N); headroom = EDFA limit − Ptotal
Use a per-channel level at the EDFA output plane for this comparison. Check the manufacturer’s gain, ASE, channel loading and saturation limits.
RXtarget = (sensitivity + overload ceiling) / 2; Acenter = max(0, RX − RXtarget)
The midpoint in dBm leaves equal dB headroom on either side. An attenuator can lower power only. Use the correct receiver plane and rated component.
Laser class comes from the equipment marking and applicable accessible emission limits. A separate +10 dBm composite advisory highlights elevated optical power for review. IEC Class 1M and Class 3B handling depends on the marked class and accessible emission conditions.
Open a scenario and edit any parameter.
FiberOpticLab
Attenuator needed. Received power exceeds the ceiling. Check the minimum and midpoint attenuation.
Class 1M equipment: viewing through collecting optics may be hazardous.
Follow IEC 60825-2 and ANSI Z136.2 procedures. Never inspect an energized fiber or connector with your eye or an optical magnifier. Verify the installed link with a calibrated power meter and field OTDR at the relevant wavelengths, using appropriate launch and receive fibers and a safe test setup.
Correct the inputs to print an engineering report.