OTDR latency, IOR error & pulse dead zone

Convert span length to one-way delay and return time. Estimate event and attenuation dead zones and check distance errors from the tester index.

Inputs

Set the true group index for the fiber and wavelength, then enter the tester setting. Use instrument-specific recovery allowances where available.

Fiber and instrument
km
ns
Resolution and tolerance
ns
ns
m
LIVE ANATOMY

OTDR reflection and recovery

OTDR reflection and recoveryONE WAY97.948µsRETURN195.896µsEVENT DZ10.516mATTEN. DZ12.251m100 ns pulseRecovery estimatedPulse10.21 mEvent DZ10.52 mAtten. DZ12.25 mDISTANCE ERROR BUDGET0 m10 m limit3.19 m left
IOR error within targetThe entered distance-error tolerance covers the calculated index mismatch.

Propagation

One-way latency
97.9478 µs
Round-trip latency
195.8955 µs
True optical span
20 km
Indicated optical span
20.00681 km
Signed distance error
6.81338 m
Signed percent error
0.03407 %

Pulse and reflection estimates

Pulse footprint
10.20952 m
Event dead zone estimate
10.51581 m
Attenuation dead zone estimate
12.25143 m

Formulas and assumptions

Time of flight

t₁ = L × ng / c; tRT = 2 × t₁

The vacuum speed is 299,792.458 km/s. Use group index because the pulse envelope determines round-trip timing.

Pulse resolution and dead zones

dz ≈ c × (pulse width + recovery allowance) / (2 × ng)

The factor of two converts return time to one-way range. EDZ estimates the distance to separate events. ADZ estimates the distance to measure a subsequent loss. Recovery allowances model the instrument response and reflection.

IOR mismatch

Lindicated = Ltrue × ng / ntester; error = Lindicated − Ltrue

A low tester index makes an unchanged time of flight look like a longer distance. Use the signed error to understand the direction.

The SMF-28 and OM4 indices are illustrative group index presets. Real dead zones depend on reflectance, receiver saturation, instrument processing and test setup. Treat calculated EDZ and ADZ as estimates and check actual instrument specifications and traces.

Worked examples

Open a scenario and edit any parameter.