Time of flight
t₁ = L × ng / c; tRT = 2 × t₁
The vacuum speed is 299,792.458 km/s. Use group index because the pulse envelope determines round-trip timing.
Estimate pulse-limited resolution at the longest pulse entry on a 120 km SMF span.
A very long pulse sacrifices closely spaced events to improve trace dynamic range.
Open the general otdr latency & dead zones calculatort₁ = L × ng / c; tRT = 2 × t₁
The vacuum speed is 299,792.458 km/s. Use group index because the pulse envelope determines round-trip timing.
dz ≈ c × (pulse width + recovery allowance) / (2 × ng)
The factor of two converts return time to one-way range. EDZ estimates the distance to separate events. ADZ estimates the distance to measure a subsequent loss. Recovery allowances model the instrument response and reflection.
Lindicated = Ltrue × ng / ntester; error = Lindicated − Ltrue
A low tester index makes an unchanged time of flight look like a longer distance. Use the signed error to understand the direction.
The SMF-28 and OM4 indices are illustrative group index presets. Real dead zones depend on reflectance, receiver saturation, instrument processing and test setup. Treat calculated EDZ and ADZ as estimates and check actual instrument specifications and traces.
Open a scenario and edit any parameter.
FiberOpticLab
IOR error within target. The entered distance-error tolerance covers the calculated index mismatch.
Follow IEC 60825-2 and ANSI Z136.2 procedures. Never inspect an energized fiber or connector with your eye or an optical magnifier. Verify the installed link with a calibrated power meter and field OTDR at the relevant wavelengths, using appropriate launch and receive fibers and a safe test setup.
Correct the inputs to print an engineering report.