Long span with 20 µs pulse

Estimate pulse-limited resolution at the longest pulse entry on a 120 km SMF span.

Inputs

Set the true group index for the fiber and wavelength, then enter the tester setting. Use instrument-specific recovery allowances where available.

Fiber and instrument
km
ns
Resolution and tolerance
ns
ns
m
LIVE ANATOMY

OTDR reflection and recovery

OTDR reflection and recoveryONE WAY587.687µsRETURN1.175msEVENT DZ2.1e+3mATTEN. DZ2.1e+3m20,000 ns pulseRecovery estimatedPulse2,041.9 mEvent DZ2,052.11 mAtten. DZ2,072.53 mDISTANCE ERROR BUDGET0 m10 m limit10 m left
IOR error within targetThe entered distance-error tolerance covers the calculated index mismatch.

Propagation

One-way latency
587.6866 µs
Round-trip latency
1.1754 ms
True optical span
120 km
Indicated optical span
120 km
Signed distance error
0 m
Signed percent error
0 %

Pulse and reflection estimates

Pulse footprint
2,041.90477 m
Event dead zone estimate
2,052.11429 m
Attenuation dead zone estimate
2,072.53334 m

What to check

A very long pulse sacrifices closely spaced events to improve trace dynamic range.

Open the general otdr latency & dead zones calculator

Formulas and assumptions

Time of flight

t₁ = L × ng / c; tRT = 2 × t₁

The vacuum speed is 299,792.458 km/s. Use group index because the pulse envelope determines round-trip timing.

Pulse resolution and dead zones

dz ≈ c × (pulse width + recovery allowance) / (2 × ng)

The factor of two converts return time to one-way range. EDZ estimates the distance to separate events. ADZ estimates the distance to measure a subsequent loss. Recovery allowances model the instrument response and reflection.

IOR mismatch

Lindicated = Ltrue × ng / ntester; error = Lindicated − Ltrue

A low tester index makes an unchanged time of flight look like a longer distance. Use the signed error to understand the direction.

The SMF-28 and OM4 indices are illustrative group index presets. Real dead zones depend on reflectance, receiver saturation, instrument processing and test setup. Treat calculated EDZ and ADZ as estimates and check actual instrument specifications and traces.

Worked examples

Open a scenario and edit any parameter.