150 m OM4 trace

Check an 850 nm OM4 fiber with a tester index of 1.480 and a 5 ns pulse.

Inputs

Set the true group index for the fiber and wavelength, then enter the tester setting. Use instrument-specific recovery allowances where available.

Fiber and instrument
km
ns
Resolution and tolerance
ns
ns
m
LIVE ANATOMY

OTDR reflection and recovery

OTDR reflection and recoveryONE WAY0.742µsRETURN1.483µsEVENT DZ0.809mATTEN. DZ2.529m5 ns pulseRecovery estimatedPulse0.51 mEvent DZ0.81 mAtten. DZ2.53 mDISTANCE ERROR BUDGET0 m0.1 m limit-0.1 m left
IOR error exceeds targetThe indicated distance differs from the true span by more than the entered tolerance.

Propagation

One-way latency
0.7415 µs
Round-trip latency
1.483 µs
True optical span
0.15 km
Indicated optical span
0.1502 km
Signed distance error
0.2027 m
Signed percent error
0.13514 %

Pulse and reflection estimates

Pulse footprint
0.50572 m
Event dead zone estimate
0.80916 m
Attenuation dead zone estimate
2.52861 m

What to check

A small IOR mismatch can exceed a tight distance target on a short run.

Open the general otdr latency & dead zones calculator

Formulas and assumptions

Time of flight

t₁ = L × ng / c; tRT = 2 × t₁

The vacuum speed is 299,792.458 km/s. Use group index because the pulse envelope determines round-trip timing.

Pulse resolution and dead zones

dz ≈ c × (pulse width + recovery allowance) / (2 × ng)

The factor of two converts return time to one-way range. EDZ estimates the distance to separate events. ADZ estimates the distance to measure a subsequent loss. Recovery allowances model the instrument response and reflection.

IOR mismatch

Lindicated = Ltrue × ng / ntester; error = Lindicated − Ltrue

A low tester index makes an unchanged time of flight look like a longer distance. Use the signed error to understand the direction.

The SMF-28 and OM4 indices are illustrative group index presets. Real dead zones depend on reflectance, receiver saturation, instrument processing and test setup. Treat calculated EDZ and ADZ as estimates and check actual instrument specifications and traces.

Worked examples

Open a scenario and edit any parameter.