10-Mil Epoxy Coating for a 10 × 12 Workshop

Estimate a thin 10-mil coating, handling reserve, and one-gallon kit count for a 120-square-foot slab.

Project inputs

Surface and coats
ft
ft
mils
mils
mils
Mix and containers
US gal
%
View shopping list

Shopping list

1 kitMixed epoxy kit 1 US gal mixed per kit · 1:1 by volume

Mixed volume with reserve
0.823 gal · 105.33 fl oz · 3.11 L
Part A
0.411 US gal
Part B
0.411 US gal
Total coat thickness
10 mils

Coating thickness section Coating thickness sectionSubstrateFlood coat10 mils120 ft² coated · 0.823 mixed US gal
Schematic layout

Worked takeoff

  1. Measure the coated face

    12 ft length × 10 ft width = 120 ft²

  2. Flood coat

    120 ft² × 10 mils thickness, plus 10% reserve = 0.823 US gal.

  3. Split the mixed volume and buy whole kits

    0.823 US gal at 1:1 by volume gives 0.411 US gal Part A and 0.411 US gal Part B. Divide by 1 US gal and round up to 1 kits.

Check before you buy

Check actual slab porosity and the kit’s stated coverage per coat. Confirm whether any primer is a separate material before setting the coat thicknesses.

Use the product’s specified mix ratio by volume, coverage, maximum layer thickness, and working time. Measure the average channel width at several points for a river and make separate takeoffs for products with different ratios.

Frequently asked questions

How many fluid ounces is this workshop coating?

At the entered thickness and 10% reserve, it is about 0.823 US gal. Multiply by 128 to get about 105 fl oz.

Would a 0.75-gallon kit cover the workshop with reserve?

The mixed demand is about 0.823 gal, so a single 0.75 gal kit is below this example’s estimate.