Freight calculation methodology
Formulas, assumptions and source references for all eight planners.
Owner-operator cost per mile
Fixed CPM = monthly fixed bills ÷ monthly milesFuel CPM = diesel price ÷ fuel economyVariable CPM = fuel CPM + reserves per mile + (driver pay + factoring + trip charges) ÷ all milesLoad net = gross invoice − (fixed CPM + variable CPM) × all miles
Use loaded and deadhead miles in the cost denominator. The breakeven invoice solves for any revenue-based pay and fees. Annual net scales the modeled trip’s net per all mile by 12 months of entered mileage. It is an operating projection before income taxes and owner draws.
Open Trucking Cost Per MileLTL density and freight class
Cubic feet = L × W × H × identical handling units ÷ 1,728PCF = total packaged pounds ÷ cubic feetNon-stackable scenario height = max(measured height, entered minimum billing height)
Measure the entire packaged envelope and include all pallet tare. The 18-class FCDC density guidelines below run from class 500 to class 50. Many commodities use the separate 13-subprovision NMFC standard scale. Use the current commodity item and carrier tariff for booking. Stowability, handling and liability can affect class.
| Density (lb/ft³) | Reference class |
|---|---|
| Below 1 | 500 |
| 1 to below 2 | 400 |
| 2 to below 3 | 300 |
| 3 to below 4 | 250 |
| 4 to below 5 | 200 |
| 5 to below 6 | 175 |
| 6 to below 7 | 150 |
| 7 to below 8 | 125 |
| 8 to below 9 | 110 |
| 9 to below 10.5 | 100 |
| 10.5 to below 12 | 92.5 |
| 12 to below 13.5 | 85 |
| 13.5 to below 15 | 77.5 |
| 15 to below 22.5 | 70 |
| 22.5 to below 30 | 65 |
| 30 to below 35 | 60 |
| 35 to below 50 | 55 |
| 50 or higher | 50 |
Pallet Ti-Hi and trailer fit
Grid Ti = floor(deck length ÷ carton length) × floor(deck width ÷ carton width)Height layers = floor((height limit − empty pallet height) ÷ carton height)Cartons = min(Ti × height layers, floor((gross limit − tare) ÷ carton weight))
We test both flat grid orientations, mixed bands in both directions and a four-block pinwheel with an optional center fill. The highest tested Ti wins. Hi counts full layers, with a possible partial layer when weight limits the stack. The trailer estimate applies available slots, usable height and cargo payload to loaded pallets.
Open Pallet Ti-Hi & Trailer FitContainer cube versus payload
Raw volume ceiling = floor(interior cube ÷ unit cube)Usable units = min(upright floor positions × usable layers, raw volume ceiling, floor(payload ÷ unit weight))Containers required = ceil(order units ÷ usable units)
The model checks the door using the narrower horizontal dimension and the upright cargo height. The upright floor layout uses the same packing comparisons as the pallet worksheet. Volume and packing bind at cube-out. Payload weight binds at weigh-out. The first floor layer fills before subsequent levels for utilization reporting.
Open Container CBM & PayloadFuel surcharge from an index
Per-mile FSC = (current index − base peg) ÷ contract MPGPercentage FSC = (index change ÷ price step) × percentage per step × linehaulEffective rate = (linehaul + FSC dollars) ÷ loaded miles
Enter the agreement’s EIA price series and release manually. For percentage-based agreements, choose prorated or completed steps. The optional zero floor removes below-peg credits. The EIA reports diesel prices and leaves surcharge formulas to the parties.
Open Fuel Surcharge & DOE IndexDeadhead, detention and counter-offer
All-mile offer rate = (linehaul + fuel) ÷ (loaded miles + deadhead miles)Detention = max(0, dock time − free time) × approved hourly rateNet per hour = (gross − operating cost − percentage fees) ÷ all on-duty hoursMinimum linehaul = max(0, operating cost ÷ (1 − fee share − net margin) − fuel − detention)
Gross includes collectible detention for the realized loaded and all-mile rates and net per hour. All dock hours remain in the time denominator. Percent fees apply to modeled gross, and the target net margin is a share of gross revenue.
Open Load Offer & DeadheadStatic axle moments and Federal Bridge Formula B
Trailer tandem reaction = (trailer tare × tare CG + cargo × cargo CG) ÷ kingpin-to-tandem distanceKingpin reaction = trailer tare + cargo − trailer tandem reactionSteer addition = kingpin reaction × fifth-wheel lead ÷ tractor wheelbaseW = 500 × [LN ÷ (N − 1) + 12N + 36], rounded to the nearest 500 lb
The remaining kingpin weight goes to the drive tandem. For Formula B, fractional spans round down to the lower whole foot as a conservative planning rule. Actual spacing controls tandem eligibility and the 36-ft paired-tandem exception. The 12,000 lb steer comparison is a planning threshold. FHWA lists a 20,000 lb federal single-axle cap. The model assumes even weight split within each tandem.
Open Axle Weight & Bridge FormulaFleet MPG, idle burn and IFTA
Fleet MPG = (taxable + non-taxable miles) ÷ total qualifying fleet gallonsTaxable gallons = jurisdiction taxable miles ÷ fleet MPGNet tax = (taxable gallons − tax-paid gallons) × tax rate + taxable gallons × surcharge rateAnnual idle gallons = weekly idle hours × gallons per hour × 52
Positive balances are estimates due and negative balances are credits. The ledger uses a single rate per jurisdiction and calculates with unrounded fleet fuel economy. Filing jurisdictions may require different rounding. The idle estimate is separate from recorded IFTA fuel.
Open Fleet MPG, Idle Cost & IFTAFrequently asked questions
How are values rounded in the freight calculation engine?
The engine retains precision through arithmetic. Whole cartons and equipment positions round down, order equipment counts round up, and Bridge Formula B rounds its result to the nearest 500 lb.
Why can a practical packing result be lower than a volume ratio?
The practical result respects discrete footprints and full layers. Packing comparisons use several tested layouts and may leave space a more complex pattern could fill.
Are operating and tax results calculated in their original display units?
The engine uses US customary physical units internally and the selected currency for money. Display conversions preserve the underlying physical quantities.