Freight calculation methodology

Formulas, assumptions and source references for all eight planners.

Owner-operator cost per mile

  • Fixed CPM = monthly fixed bills ÷ monthly miles
  • Fuel CPM = diesel price ÷ fuel economy
  • Variable CPM = fuel CPM + reserves per mile + (driver pay + factoring + trip charges) ÷ all miles
  • Load net = gross invoice − (fixed CPM + variable CPM) × all miles

Use loaded and deadhead miles in the cost denominator. The breakeven invoice solves for any revenue-based pay and fees. Annual net scales the modeled trip’s net per all mile by 12 months of entered mileage. It is an operating projection before income taxes and owner draws.

Open Trucking Cost Per Mile

LTL density and freight class

  • Cubic feet = L × W × H × identical handling units ÷ 1,728
  • PCF = total packaged pounds ÷ cubic feet
  • Non-stackable scenario height = max(measured height, entered minimum billing height)

Measure the entire packaged envelope and include all pallet tare. The 18-class FCDC density guidelines below run from class 500 to class 50. Many commodities use the separate 13-subprovision NMFC standard scale. Use the current commodity item and carrier tariff for booking. Stowability, handling and liability can affect class.

18-class FCDC density guidelines
Density (lb/ft³)Reference class
Below 1500
1 to below 2400
2 to below 3300
3 to below 4250
4 to below 5200
5 to below 6175
6 to below 7150
7 to below 8125
8 to below 9110
9 to below 10.5100
10.5 to below 1292.5
12 to below 13.585
13.5 to below 1577.5
15 to below 22.570
22.5 to below 3065
30 to below 3560
35 to below 5055
50 or higher50
Open LTL Density & Freight Class

Pallet Ti-Hi and trailer fit

  • Grid Ti = floor(deck length ÷ carton length) × floor(deck width ÷ carton width)
  • Height layers = floor((height limit − empty pallet height) ÷ carton height)
  • Cartons = min(Ti × height layers, floor((gross limit − tare) ÷ carton weight))

We test both flat grid orientations, mixed bands in both directions and a four-block pinwheel with an optional center fill. The highest tested Ti wins. Hi counts full layers, with a possible partial layer when weight limits the stack. The trailer estimate applies available slots, usable height and cargo payload to loaded pallets.

Open Pallet Ti-Hi & Trailer Fit

Container cube versus payload

  • Raw volume ceiling = floor(interior cube ÷ unit cube)
  • Usable units = min(upright floor positions × usable layers, raw volume ceiling, floor(payload ÷ unit weight))
  • Containers required = ceil(order units ÷ usable units)

The model checks the door using the narrower horizontal dimension and the upright cargo height. The upright floor layout uses the same packing comparisons as the pallet worksheet. Volume and packing bind at cube-out. Payload weight binds at weigh-out. The first floor layer fills before subsequent levels for utilization reporting.

Open Container CBM & Payload

Fuel surcharge from an index

  • Per-mile FSC = (current index − base peg) ÷ contract MPG
  • Percentage FSC = (index change ÷ price step) × percentage per step × linehaul
  • Effective rate = (linehaul + FSC dollars) ÷ loaded miles

Enter the agreement’s EIA price series and release manually. For percentage-based agreements, choose prorated or completed steps. The optional zero floor removes below-peg credits. The EIA reports diesel prices and leaves surcharge formulas to the parties.

Open Fuel Surcharge & DOE Index

Deadhead, detention and counter-offer

  • All-mile offer rate = (linehaul + fuel) ÷ (loaded miles + deadhead miles)
  • Detention = max(0, dock time − free time) × approved hourly rate
  • Net per hour = (gross − operating cost − percentage fees) ÷ all on-duty hours
  • Minimum linehaul = max(0, operating cost ÷ (1 − fee share − net margin) − fuel − detention)

Gross includes collectible detention for the realized loaded and all-mile rates and net per hour. All dock hours remain in the time denominator. Percent fees apply to modeled gross, and the target net margin is a share of gross revenue.

Open Load Offer & Deadhead

Static axle moments and Federal Bridge Formula B

  • Trailer tandem reaction = (trailer tare × tare CG + cargo × cargo CG) ÷ kingpin-to-tandem distance
  • Kingpin reaction = trailer tare + cargo − trailer tandem reaction
  • Steer addition = kingpin reaction × fifth-wheel lead ÷ tractor wheelbase
  • W = 500 × [LN ÷ (N − 1) + 12N + 36], rounded to the nearest 500 lb

The remaining kingpin weight goes to the drive tandem. For Formula B, fractional spans round down to the lower whole foot as a conservative planning rule. Actual spacing controls tandem eligibility and the 36-ft paired-tandem exception. The 12,000 lb steer comparison is a planning threshold. FHWA lists a 20,000 lb federal single-axle cap. The model assumes even weight split within each tandem.

Open Axle Weight & Bridge Formula

Fleet MPG, idle burn and IFTA

  • Fleet MPG = (taxable + non-taxable miles) ÷ total qualifying fleet gallons
  • Taxable gallons = jurisdiction taxable miles ÷ fleet MPG
  • Net tax = (taxable gallons − tax-paid gallons) × tax rate + taxable gallons × surcharge rate
  • Annual idle gallons = weekly idle hours × gallons per hour × 52

Positive balances are estimates due and negative balances are credits. The ledger uses a single rate per jurisdiction and calculates with unrounded fleet fuel economy. Filing jurisdictions may require different rounding. The idle estimate is separate from recorded IFTA fuel.

Open Fleet MPG, Idle Cost & IFTA

Frequently asked questions

How are values rounded in the freight calculation engine?

The engine retains precision through arithmetic. Whole cartons and equipment positions round down, order equipment counts round up, and Bridge Formula B rounds its result to the nearest 500 lb.

Why can a practical packing result be lower than a volume ratio?

The practical result respects discrete footprints and full layers. Packing comparisons use several tested layouts and may leave space a more complex pattern could fill.

Are operating and tax results calculated in their original display units?

The engine uses US customary physical units internally and the selected currency for money. Display conversions preserve the underlying physical quantities.