Closed traverse adjustment

Find latitude and departure misclosure, check relative precision, and balance a three- to six-course loop.

Worked examples

Field inputs

Switching the unit converts the inputs.

Traverse control
Measured courses

Enter courses in walking order, including the final course back to the start.

Survey anatomy

Raw & balanced traverse

Edit inputs
Raw & balanced traverseLive plot with four readings and a check bar. Measured closure. Within target.MISCLOSURE0.0436mPRECISION11,6991 : NCLOSE LIMIT0.102mENCLOSED15,753.79m²RAWBALANCED1234CLOSURE INSET0.0436 mMeasured closureWithin target
Diagram proportions adapt to the inputs. Use the computed readings for field dimensions.

Computed results

Within target

Measured closure

Measured length
510.061m
Σ Latitude ΔN
−0.026m
Σ Departure ΔE
−0.035m
Linear misclosure
0.0436m
Relative precision
1 : 11,698.52
Project closure limit
0.10201m

Balanced enclosure

Adjusted ΣΔN
0m
Adjusted ΣΔE
0m
Adjusted area
15,753.7875m²
Square feet
169,572.3574ft²
Acres
3.89285ac
Hectares
1.57538ha

Measured courses

LegAzimuth°LengthmΔNmΔEm
1901500150
201051050
3270150.0350−150.035
4180105.026−105.0260

Bowditch adjustments

LegcNmcEmAdj. ΔNmAdj. ΔEmAdj. NmAdj. Em
10.007650.010290.00765150.010291,200.007651,000.01029
20.005350.00721105.005350.007211,305.0131,000.0175
30.007650.01030.00765−150.02471,305.02065849.99279
40.005350.00721−105.020650.007211,200850

Formulas and conventions

Compute measured closure

ΔNᵢ = dᵢ cos(αᵢ) · ΔEᵢ = dᵢ sin(αᵢ) · e = √((ΣΔN)² + (ΣΔE)²)

Use oriented azimuths or quadrant bearings and horizontal distances around the entire loop. Relative precision is 1 : (total length ÷ e). An exactly closed loop has zero misclosure and no finite precision denominator.

Balance by the compass rule

cNᵢ = −ΣΔN × dᵢ ÷ Σd · cEᵢ = −ΣΔE × dᵢ ÷ Σd

Corrections are proportional to course length. The adjusted leg components sum to zero, with any binary rounding remainder absorbed on the closing course. Inspect angular closure and blunders before using the adjustment.

Check against a project target

Closure limit = Σd ÷ target denominator

The selected precision target applies to the measured closure. Area comes from the adjusted polygon in local coordinates. Crossed, overlapping, or degenerate adjusted boundaries cannot produce an enclosed parcel area.

Worked examples

Open a case to edit its inputs and compare the original checks.

Share editable inputs

The link contains the entered field values. Share it with people who should see those values.