Perfect closure of a 120 by 80 m rectangle

Verify exact cardinal closure and the area of a four-course rectangle.

More examples

Field inputs

Switching the unit converts the inputs.

Traverse control
Measured courses

Enter courses in walking order, including the final course back to the start.

Survey anatomy

Raw & balanced traverse

Edit inputs
Raw & balanced traverseLive plot with four readings and a check bar. Measured closure. Within target.MISCLOSURE0mPRECISIONExactCLOSE LIMIT0.08mENCLOSED9,600m²RAWBALANCED1234CLOSURE INSET0 mMeasured closureWithin target
Diagram proportions adapt to the inputs. Use the computed readings for field dimensions.

Computed results

Within target

Measured closure

Measured length
400m
Σ Latitude ΔN
0m
Σ Departure ΔE
0m
Linear misclosure
0m
Relative precision
Exact closure
Project closure limit
0.08m

Balanced enclosure

Adjusted ΣΔN
0m
Adjusted ΣΔE
0m
Adjusted area
9,600m²
Square feet
103,333.54ft²
Acres
2.37221ac
Hectares
0.96ha

Measured courses

LegAzimuth°LengthmΔNmΔEm
1901200120
2080800
32701200−120
418080−800

Bowditch adjustments

LegcNmcEmAdj. ΔNmAdj. ΔEmAdj. NmAdj. Em
10001201,200970
2008001,280970
3000−1201,280850
400−80−01,200850

Worked check

The opposing distances cancel. The loop is 400 m long, its measured endpoint is at the start, and the adjusted enclosure is 120 × 80 m².

Measured misclosure (m)
0
Measured length (m)
400
Balanced area (m²)
9,600

These checks describe the original example. Reset restores the original inputs.

Formulas and conventions

Compute measured closure

ΔNᵢ = dᵢ cos(αᵢ) · ΔEᵢ = dᵢ sin(αᵢ) · e = √((ΣΔN)² + (ΣΔE)²)

Use oriented azimuths or quadrant bearings and horizontal distances around the entire loop. Relative precision is 1 : (total length ÷ e). An exactly closed loop has zero misclosure and no finite precision denominator.

Balance by the compass rule

cNᵢ = −ΣΔN × dᵢ ÷ Σd · cEᵢ = −ΣΔE × dᵢ ÷ Σd

Corrections are proportional to course length. The adjusted leg components sum to zero, with any binary rounding remainder absorbed on the closing course. Inspect angular closure and blunders before using the adjustment.

Check against a project target

Closure limit = Σd ÷ target denominator

The selected precision target applies to the measured closure. Area comes from the adjusted polygon in local coordinates. Crossed, overlapping, or degenerate adjusted boundaries cannot produce an enclosed parcel area.

More worked examples

Open a case to edit its inputs and compare the original checks.

Share editable inputs

The link contains the entered field values. Share it with people who should see those values.