A First Order Class II loop over the limit

Compare six millimeters of misclosure with the tighter five-millimeter threshold.

More examples

Field inputs

Switching the unit converts the inputs.

Benchmark and order

Leave the end elevation blank to close on the starting benchmark. A different end benchmark uses the loop limit as a comparison only.

Level book

Run is the distance between turning points. IS at is the optional distance from the preceding point. A blank IS offset uses half the run.

Survey anatomy

Height-of-instrument profile

Edit inputs
Height-of-instrument profileLive plot with four readings and a check bar. FGCS loop closure. Above loop limit.MISCLOSURE6mmLOOP LIMIT5mmEND OBSERVED100.006mRUN LENGTH1,000mOBSERVEDADJUSTEDSTART BMEND BMFGCS loop closureAbove loop limit
Diagram proportions adapt to the inputs. Use the computed readings for field dimensions.

Computed results

Above loop limit

Level-book arithmetic

Σ Backsights
1.006m
Σ Foresights
1m
ΣBS − ΣFS
0.006m
Observed end − start
0.006m
Arithmetic residual
0m

Benchmark closure

Observed end elevation
100.006m
Known / adjusted end
100m
Signed misclosure
0.006m
Signed misclosure
6mm
Total run
1km
FGCS loop limit
5mm
Selected order
First · Class II

Height-of-instrument reductions

PointRun atmHImRodmObservedmCorrectionmAdjustedm
End BM1,000101.0061100.006−0.006100

Worked check

First Order Class II gives a 5 mm limit at 1 km. A 6 mm closure calls for investigation before using any balanced elevations.

Loop limit (mm)
5
Within loop limit
No

These checks describe the original example. Reset restores the original inputs.

Formulas and conventions

Reduce rod readings

HI = previous elevation + BS · Point elevation = HI − IS or FS

Each foresight moves the level book to the next turning point. Intermediate readings share the setup HI. The arithmetic check computes ΣBS − ΣFS and the end-minus-start difference on a shared decimal grid.

Compare the FGCS loop limit

Tolerance in mm = C√K · K = loop length in kilometers

C is 4 for First Class I, 5 for First Class II, 6 for Second Class I, 8 for Second Class II, and 12 for Third Order. These are loop coefficients. FGCS classification also depends on field procedures, equipment, ties, and other checks.

Distribute elevation correction

Correction at d = −misclosure × d ÷ total run

Misclosure is the measured end elevation minus the known end elevation. Use cumulative distance for turning points and intermediate sights. When IS at is blank, the intermediate sight is placed halfway along its setup run.

More worked examples

Open a case to edit its inputs and compare the original checks.

Share editable inputs

The link contains the entered field values. Share it with people who should see those values.