Differential leveling calculator

Reduce backsights, intermediate sights and foresights, then compare and distribute benchmark loop misclosure.

Worked examples

Field inputs

Switching the unit converts the inputs.

Benchmark and order

Leave the end elevation blank to close on the starting benchmark. A different end benchmark uses the loop limit as a comparison only.

Level book

Run is the distance between turning points. IS at is the optional distance from the preceding point. A blank IS offset uses half the run.

Survey anatomy

Height-of-instrument profile

Edit inputs
Height-of-instrument profileLive plot with four readings and a check bar. FGCS loop closure. Within loop limit.MISCLOSURE3mmLOOP LIMIT4.1569mmEND OBSERVED100.003mRUN LENGTH480mOBSERVEDADJUSTEDSTART BMEND BMFGCS loop closureWithin loop limit
Diagram proportions adapt to the inputs. Use the computed readings for field dimensions.

Computed results

Within loop limit

Level-book arithmetic

Σ Backsights
5.13m
Σ Foresights
5.127m
ΣBS − ΣFS
0.003m
Observed end − start
0.003m
Arithmetic residual
0m

Benchmark closure

Observed end elevation
100.003m
Known / adjusted end
100m
Signed misclosure
0.003m
Signed misclosure
3mm
Total run
0.48km
FGCS loop limit
4.15692mm
Selected order
Second · Class I

Height-of-instrument reductions

PointRun atmHImRodmObservedmCorrectionmAdjustedm
IS 152101.421.11100.31−0.00033100.30968
TP 1125101.420.875100.545−0.00078100.54422
TP 2235101.7711.81299.959−0.0014799.95753
IS 3300101.3451.76599.58−0.0018899.57813
TP 3365101.3451.12100.225−0.00228100.22272
End BM480101.3231.32100.003−0.003100

Formulas and conventions

Reduce rod readings

HI = previous elevation + BS · Point elevation = HI − IS or FS

Each foresight moves the level book to the next turning point. Intermediate readings share the setup HI. The arithmetic check computes ΣBS − ΣFS and the end-minus-start difference on a shared decimal grid.

Compare the FGCS loop limit

Tolerance in mm = C√K · K = loop length in kilometers

C is 4 for First Class I, 5 for First Class II, 6 for Second Class I, 8 for Second Class II, and 12 for Third Order. These are loop coefficients. FGCS classification also depends on field procedures, equipment, ties, and other checks.

Distribute elevation correction

Correction at d = −misclosure × d ÷ total run

Misclosure is the measured end elevation minus the known end elevation. Use cumulative distance for turning points and intermediate sights. When IS at is blank, the intermediate sight is placed halfway along its setup run.

Worked examples

Open a case to edit its inputs and compare the original checks.

Share editable inputs

The link contains the entered field values. Share it with people who should see those values.