A 20° curve with nominal chord stationing

Compare nominal 100 ft chord stations with the longer true arc.

More examples

Field inputs

Switching the unit converts the inputs.

Circular geometry

A 100 ft reference is customary in U.S. work. Match the reference length and definition stated on the plans.

Stationing and staking

Use plain distances or station notation. Deflections are measured from the tangent at PC.

Survey anatomy

Circular curve stationing

Edit inputs
Circular curve stationingLive plot with four readings and a check bar. Intersection sweep. 60° / 180°.RADIUS287.9385ftTRUE ARC301.5285ftTANGENT166.2414ftLONG CHORD287.9385ftPCPTPILONG CHORDRIGHT TURNIntersection sweep60° / 180°
Diagram proportions adapt to the inputs. Use the computed readings for field dimensions.

Computed results

60° / 180°

Station labels use the nominal chord span. Arc offsets and straight stake chords use exact circular geometry.

Circular curve elements

Radius R
287.93852ft
Tangent T
166.24138ft
True arc length
301.52852ft
Long chord LC
287.93852ft
External E
44.54424ft
Middle ordinate M
38.57645ft
Reference arc degree
19.898615°
Reference chord degree
20°

Control stations

PC · Curvature
13+33.759ft
PI · Intersection
15+00.000ft
PT · Tangency
16+33.759ft
Station span
300ft
PT deflection from PC
30°

Deflections and subchords

PointStationftArc from PCftDeflection°SubchordftChord from PCft
PC13+33.7590000
Stake13+50.00016.324141.6241416.3219516.32195
Stake14+00.00066.578896.6241450.1909966.43067
Stake14+50.000116.8336411.6241450.19099116.03381
Stake15+00.000167.0883916.6241450.19099164.75386
Stake15+50.000217.3431521.6241450.19099212.22004
Stake16+00.000267.597926.6241450.19099258.07109
PT16+33.759301.528523033.91099287.93852

Worked check

A 100 ft chord subtends 20° and sets the radius. Three nominal chord units give a 300 ft station span. The true arc remains Rπ/3.

Radius (ft)
287.9385242
Nominal station span (ft)
300
True arc length (ft)
301.5285174

These checks describe the original example. Reset restores the original inputs.

Formulas and conventions

Choose a degree convention

R = b ÷ Dᵣₐd (arc) · R = b ÷ [2 sin(D ÷ 2)] (chord)

The reference length b is a 100 ft arc or chord by common U.S. convention. It is editable for project-specific bases. True arc stationing is the highway default. Nominal chord stationing uses bΔ ÷ Dchord and reports true arc length separately.

Locate PC, PI and PT

T = R tan(Δ ÷ 2) · Arc = RΔᵣₐd · PC = PI − T · PT = PC + station span

The long chord is 2R sin(Δ ÷ 2). External distance is T tan(Δ ÷ 4). Middle ordinate is R[1 − cos(Δ ÷ 2)]. The field sketch mirrors for left-hand turns.

Stake from the tangent at PC

Deflection = θ ÷ 2 · Subchord = 2R sin[(θᵢ − θᵢ₋₁) ÷ 2]

Place stakes at even station-interval multiples between the two endpoints. Compute θ as the fraction of station span times Δ and use circular geometry for exact straight chords. Left deflection is negative.

More worked examples

Open a case to edit its inputs and compare the original checks.

Share editable inputs

The link contains the entered field values. Share it with people who should see those values.