Concave woodlot and broad midsection

Subtract a triangular notch and check a negative prismoidal correction.

More examples

Field inputs

Switching the unit converts the inputs.

Parcel boundary
Boundary coordinates

Walk the perimeter clockwise or counterclockwise. The final corner closes to the first automatically.

Roadway cross sections

Use measured areas of the same cut or fill category. Enter the section halfway between the end stations.

Survey anatomy

Parcel & roadway cross sections

Edit inputs
Parcel & roadway cross sectionsLive plot with four readings and a check bar. Shoelace / DMD check. Areas agree.PARCEL AREA1,800m²PERIMETER212.111mPRISMOID1,050m³CORRECTION−300m³PARCELEND & MID SECTIONSP1P2P3P4P5A1AMA2Shoelace / DMD checkAreas agree
Diagram proportions adapt to the inputs. Use the computed readings for field dimensions.

Computed results

Areas agree

Boundary geometry

Shoelace area
1,800m²
Square feet
19,375.03875ft²
Acres
0.44479ac
Hectares
0.18ha
DMD area
1,800m²
Perimeter
212.11103m
Point order
Counterclockwise

Roadway volumes

Average end area
750m³
Average end area
980.96296yd³
Prismoidal volume
1,050m³
Prismoidal volume
1,373.34815yd³
Correction Cₚ
−300m³
Correction Cₚ
−392.38519yd³

Boundary courses and DMD

LegStart NmStart EmΔNmΔEmDMDmDMD × ΔNm²
100060600
20604001204,800
34060−20−3090−1,800
4203020−3030600
5400−4000−0

Worked check

Subtract the 600 m² notch from the 2,400 m² rectangle. The large midsection makes the prismoidal volume 300 m³ greater than average end area.

Enclosed area (m²)
1,800
DMD area (m²)
1,800
Prismoidal correction (m³)
−300

These checks describe the original example. Reset restores the original inputs.

Formulas and conventions

Compute plane-coordinate area

Signed double area = Σ(EᵢNᵢ₊₁ − Eᵢ₊₁Nᵢ)

Use three to eight distinct corners in perimeter order. The perimeter sums straight edges. The absolute half-sum is enclosed area. Positive signed area corresponds to counterclockwise order in a north-up plan.

Cross-check by DMD

DMD₁ = ΔE₁ · DMDᵢ = DMDᵢ₋₁ + ΔEᵢ₋₁ + ΔEᵢ · Area = |Σ(DMDᵢΔNᵢ)| ÷ 2

Both methods translate to a local origin before calculation. Acres use the International-foot definition; square U.S. survey feet are also reported when that working unit is selected.

Compare two roadway section volumes

AEA = L(A₁ + A₂) ÷ 2 · V = L(A₁ + 4Aₘ + A₂) ÷ 6 · Cₚ = AEA − V

Take Aₘ at the true midpoint. The prismoidal formula is exact for a prismoid and for a quadratic cross-section area profile. Compare like cut or fill areas. Positive Cₚ means average end area overstates the prismoidal volume.

More worked examples

Open a case to edit its inputs and compare the original checks.

Share editable inputs

The link contains the entered field values. Share it with people who should see those values.