Concave woodlot and broad midsection
Subtract a triangular notch and check a negative prismoidal correction.
More examplesSurvey anatomy
Parcel & roadway cross sections
Computed results
Areas agree
Boundary geometry
- Shoelace area
- 1,800m²
- Square feet
- 19,375.03875ft²
- Acres
- 0.44479ac
- Hectares
- 0.18ha
- DMD area
- 1,800m²
- Perimeter
- 212.11103m
- Point order
- Counterclockwise
Roadway volumes
- Average end area
- 750m³
- Average end area
- 980.96296yd³
- Prismoidal volume
- 1,050m³
- Prismoidal volume
- 1,373.34815yd³
- Correction Cₚ
- −300m³
- Correction Cₚ
- −392.38519yd³
Boundary courses and DMD
| Leg | Start Nm | Start Em | ΔNm | ΔEm | DMDm | DMD × ΔNm² |
|---|---|---|---|---|---|---|
| 1 | 0 | 0 | 0 | 60 | 60 | 0 |
| 2 | 0 | 60 | 40 | 0 | 120 | 4,800 |
| 3 | 40 | 60 | −20 | −30 | 90 | −1,800 |
| 4 | 20 | 30 | 20 | −30 | 30 | 600 |
| 5 | 40 | 0 | −40 | 0 | 0 | −0 |
Worked check
Subtract the 600 m² notch from the 2,400 m² rectangle. The large midsection makes the prismoidal volume 300 m³ greater than average end area.
- Enclosed area (m²)
- 1,800
- DMD area (m²)
- 1,800
- Prismoidal correction (m³)
- −300
These checks describe the original example. Reset restores the original inputs.
Formulas and conventions
Compute plane-coordinate area
Signed double area = Σ(EᵢNᵢ₊₁ − Eᵢ₊₁Nᵢ)
Use three to eight distinct corners in perimeter order. The perimeter sums straight edges. The absolute half-sum is enclosed area. Positive signed area corresponds to counterclockwise order in a north-up plan.
Cross-check by DMD
DMD₁ = ΔE₁ · DMDᵢ = DMDᵢ₋₁ + ΔEᵢ₋₁ + ΔEᵢ · Area = |Σ(DMDᵢΔNᵢ)| ÷ 2
Both methods translate to a local origin before calculation. Acres use the International-foot definition; square U.S. survey feet are also reported when that working unit is selected.
Compare two roadway section volumes
AEA = L(A₁ + A₂) ÷ 2 · V = L(A₁ + 4Aₘ + A₂) ÷ 6 · Cₚ = AEA − V
Take Aₘ at the true midpoint. The prismoidal formula is exact for a prismoid and for a quadratic cross-section area profile. Compare like cut or fill areas. Positive Cₚ means average end area overstates the prismoidal volume.
More worked examples
Open a case to edit its inputs and compare the original checks.
- Rectangular parcel and constant section
Check a 60 by 40 m parcel and a constant-area roadway section.
- Triangular parcel and roadway wedge
Compute a right-triangle parcel and check a linearly changing end area.
- Clockwise legacy survey-foot parcel
Check a clockwise 43,560 ftUS² enclosure and volume conversion from survey-foot sections.
- Eight corners at large grid coordinates
Check a chamfered block without losing precision to large coordinate offsets.
- Positive prismoidal correction in a roadway reach
Compare unequal end areas with a midsection smaller than their average.
GeoSurveyLab · Field calculation
Concave woodlot and broad midsection
Areas agree
Field inputs
- Working unit
- Meters (m)
- Number of corners
- 5
- Boundary coordinates 1
- 0 / 0
- Boundary coordinates 2
- 0 / 60
- Boundary coordinates 3
- 40 / 60
- Boundary coordinates 4
- 20 / 30
- Boundary coordinates 5
- 40 / 0
- Station separation
- 30 m
- First section A₁
- 20 m²
- Midsection Aₘ
- 40 m²
- Last section A₂
- 30 m²
Boundary geometry
- Shoelace area
- 1,800m²
- Square feet
- 19,375.0388ft²
- Acres
- 0.4448ac
- Hectares
- 0.18ha
- DMD area
- 1,800m²
- Perimeter
- 212.111m
- Point order
- Counterclockwise
Roadway volumes
- Average end area
- 750m³
- Average end area
- 980.963yd³
- Prismoidal volume
- 1,050m³
- Prismoidal volume
- 1,373.3482yd³
- Correction Cₚ
- −300m³
- Correction Cₚ
- −392.3852yd³
Boundary courses and DMD
| Leg | Start Nm | Start Em | ΔNm | ΔEm | DMDm | DMD × ΔNm² |
|---|---|---|---|---|---|---|
| 1 | 0 | 0 | 0 | 60 | 60 | 0 |
| 2 | 0 | 60 | 40 | 0 | 120 | 4,800 |
| 3 | 40 | 60 | −20 | −30 | 90 | −1,800 |
| 4 | 20 | 30 | 20 | −30 | 30 | 600 |
| 5 | 40 | 0 | −40 | 0 | 0 | −0 |
For planning, training, and independent checks. Have a locally licensed Professional Land Surveyor (PLS) verify legal boundaries and survey control. Have a licensed Professional Engineer (PE) verify engineering layout and design where required.