Total station EDM calculator

Reduce slope distance and zenith or vertical angle to horizontal distance, ground elevation change and target elevation.

Worked examples

Field inputs

Switching the unit converts the inputs.

Total station shot
Curvature and refraction

Use zero ppm for a distance already scaled by the instrument. Zenith is 0° straight up. Vertical angles are signed from level.

Survey anatomy

Sightline & vertical reduction

Edit inputs
Sightline & vertical reductionLive plot with four readings and a check bar. C/R review limit. Within limit.HORIZONTAL819.9543mGROUND ΔZ9.3464mC/R ADDED0.0454mTARGET ELEV.351.8464mOCCUPIEDTARGETSIGHTLINEC/R EXAGGERATEDC/R review limitWithin limit
Diagram proportions adapt to the inputs. Use the computed readings for field dimensions.

Computed results

Within limit

Slope reduction

Raw slope distance
820m
Scaled slope distance
820.00984m
Vertical angle
0.666667°
Zenith angle
89.333333°
Horizontal distance
819.95433m
Axis-to-prism ΔZ
9.54103m

Ground elevation

Occupied point
342.5m
Curvature / refraction
0.04538m
Ground-to-ground ΔZ
9.34641m
Target point
351.84641m
C/R review limit
0.05m

Formulas and conventions

Scale and resolve the shot

S corrected = S(1 + ppm ÷ 10⁶) · HD = S corrected cos(v) · VD = S corrected sin(v)

Vertical angle v is positive above level. For a zenith reading Z, v = 90° − Z. Set ppm to zero for a distance the instrument already corrected.

Apply curvature and refraction once

C/R = +0.0675K² m · equivalently ≈ +0.0206M² ft

K is horizontal distance in kilometers. M is horizontal distance in thousands of feet. The calculator evaluates the metric expression and converts the result to preserve a consistent correction across units. Use Off / already applied if the instrument has made this correction.

Compute the ground-to-ground change

ΔZ = HI + VD + C/R − HT · Target elevation = occupied elevation + ΔZ

The review limit flags when the correction itself is larger than your chosen value. The approximation models standard refraction. Actual refraction varies with the air path, especially near the ground.

Worked examples

Open a case to edit its inputs and compare the original checks.

Share editable inputs

The link contains the entered field values. Share it with people who should see those values.