Curvature correction at 1,000 ft
Relate the customary coefficient in feet to the unit-consistent metric expression.
More examplesSurvey anatomy
Sightline & vertical reduction
Computed results
Within limit
Slope reduction
- Raw slope distance
- 1,000ft
- Scaled slope distance
- 1,000ft
- Vertical angle
- 0°
- Zenith angle
- 90°
- Horizontal distance
- 1,000ft
- Axis-to-prism ΔZ
- 0ft
Ground elevation
- Occupied point
- 250ft
- Curvature / refraction
- 0.02057ft
- Ground-to-ground ΔZ
- 0.02057ft
- Target point
- 250.02057ft
- C/R review limit
- 0.16404ft
Worked check
One thousand International feet is 0.3048 km. The metric model converted back to feet yields 0.020574 ft, or about 0.0206 ft.
- Curvature and refraction (ft)
- 0.020574
- Target elevation (ft)
- 250.020574
These checks describe the original example. Reset restores the original inputs.
Formulas and conventions
Scale and resolve the shot
S corrected = S(1 + ppm ÷ 10⁶) · HD = S corrected cos(v) · VD = S corrected sin(v)
Vertical angle v is positive above level. For a zenith reading Z, v = 90° − Z. Set ppm to zero for a distance the instrument already corrected.
Apply curvature and refraction once
C/R = +0.0675K² m · equivalently ≈ +0.0206M² ft
K is horizontal distance in kilometers. M is horizontal distance in thousands of feet. The calculator evaluates the metric expression and converts the result to preserve a consistent correction across units. Use Off / already applied if the instrument has made this correction.
Compute the ground-to-ground change
ΔZ = HI + VD + C/R − HT · Target elevation = occupied elevation + ΔZ
The review limit flags when the correction itself is larger than your chosen value. The approximation models standard refraction. Actual refraction varies with the air path, especially near the ground.
More worked examples
Open a case to edit its inputs and compare the original checks.
- One-kilometer level sightline
Isolate the combined curvature and refraction correction on a level shot.
- A 30° uphill vertical angle
Resolve a 200 m slope shot and account for unequal instrument and prism heights.
- A descending shot at zenith 120°
Use a zenith angle greater than 90° to compute a negative vertical component.
- A +20 ppm atmospheric distance scale
Apply a measured atmospheric scale correction to a raw 1,500 m slope distance.
- Vertical zenith shot in U.S. survey feet
Confirm that a pure vertical shot has zero horizontal distance and zero curvature correction.
GeoSurveyLab · Field calculation
Curvature correction at 1,000 ft
Within limit
Field inputs
- Working unit
- International foot (ft)
- Slope distance
- 1000 ft
- EDM scale correction
- 0 ppm
- Angle reference
- Zenith angle
- Observed angle
- 90 °
- Instrument height HI
- 5 ft
- Prism height HT
- 5 ft
- Occupied elevation
- 250 ft
- Correction
- Apply to raw shot
- Correction review limit
- 0.1640419947506562 ft
Slope reduction
- Raw slope distance
- 1,000ft
- Scaled slope distance
- 1,000ft
- Vertical angle
- 0°
- Zenith angle
- 90°
- Horizontal distance
- 1,000ft
- Axis-to-prism ΔZ
- 0ft
Ground elevation
- Occupied point
- 250ft
- Curvature / refraction
- 0.0206ft
- Ground-to-ground ΔZ
- 0.0206ft
- Target point
- 250.0206ft
- C/R review limit
- 0.164ft
For planning, training, and independent checks. Have a locally licensed Professional Land Surveyor (PLS) verify legal boundaries and survey control. Have a licensed Professional Engineer (PE) verify engineering layout and design where required.