Infinite slope stability
Compare dry, parallel-seepage and pseudo-static factors of safety for a shallow slip plane.
Results
Edit inputs ↓- Static F.S.
- 1.55
- Seismic F.S.
- 1.29
- Dry F.S.
- 1.8
- Pore ratio
- 0.148
- Slip plane
- Phreatic line
- Driving load
Computed factors meet the displayed slope screening limits.
Calculation details
| Average soil unit weight | 18.7 kN/m³ |
|---|---|
| Slip-plane pore pressure u | 4.16 kPa |
| Static effective normal stress | 18.5 kPa |
| Static driving shear stress | 11.05 kPa |
| Seismic effective normal stress | 17.62 kPa |
| Seismic driving shear stress | 12.86 kPa |
| Static F.S. minus 1.50 | 0.049 |
| Seismic F.S. minus 1.10 | 0.189 |
GeotechSoilLab · Screening sheet · Metric SI
Infinite slope stability
| Slope angle β | 26 ° |
|---|---|
| Vertical plane depth z | 1.5 m |
| Cohesion c′ | 6 kPa |
| Friction angle φ′ | 31 ° |
| Moist weight γ | 18 kN/m³ |
| Saturated weight γsat | 20 kN/m³ |
| Water height ratio m | 0.35 |
| Seismic coefficient kh | 0.08 |
| Static F.S. | 1.55 |
|---|---|
| Seismic F.S. | 1.29 |
| Dry F.S. | 1.8 |
| Pore ratio | 0.148 |
| Average soil unit weight | 18.7 kN/m³ |
| Slip-plane pore pressure u | 4.16 kPa |
| Static effective normal stress | 18.5 kPa |
| Static driving shear stress | 11.05 kPa |
| Seismic effective normal stress | 17.62 kPa |
| Seismic driving shear stress | 12.86 kPa |
| Static F.S. minus 1.50 | 0.049 |
| Seismic F.S. minus 1.10 | 0.189 |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Method & assumptions
- Plane depth z is vertical. Average soil weight is γ(1 − m) + γsat m, where m is saturated height divided by z. Parallel seepage gives u = γw m z cos²β. The pore-pressure ratio is u divided by total vertical stress.
- Static F.S. = [c′ + (σv cos²β − u) tan φ′]/(σv sinβ cosβ). The dry reference uses the moist unit weight and u = 0.
- The horizontal down-slope inertial force subtracts kh σv sinβ cosβ from effective normal stress and adds kh σv cos²β to driving shear. Vertical acceleration and seismic pore-pressure generation are outside this model.
- The sample thresholds are 1.50 static and 1.10 pseudo-static. A nonpositive effective normal stress makes the frictional seismic screen unavailable. Use a different stability model for deep, circular or nonparallel failure.
Worked examples
- Dry frictional soil slopeA dry granular slope has a shallow plane parallel to the ground surface.
- Slope saturated to the surfaceLong-duration seepage brings the phreatic line to the slope surface.
- Slope with a halfway phreatic lineGroundwater occupies the lower half of a thin residual-soil layer over bedrock.
- Pseudo-static slope with horizontal loadingA preliminary seismic screen applies a horizontal inertia coefficient on a shallow sliding layer.
- Steep slope below the static targetA steep saturated residual-soil slope has modest cohesion and a shallow planar slip surface.