Worked example

Seismic slope with loss of normal contact

A deliberately severe combination sets the phreatic line at grade and applies strong downslope acceleration.

Static F.S.
0.43
Seismic F.S.
—
Dry F.S.
0.65
Pore ratio
0.115
Slope slice & parallel slip plane Schematic
Slope slice & parallel slip plane, schematic Slope 61°z 1.6 mWater ratio 1kₕ 0.55Static / 1.500.43Seismic / 1.10—
  • Slip plane
  • Phreatic line
  • Driving load

At least one applicable slope factor falls below the displayed screening limit. The seismic case loses effective normal contact. A frictional sliding factor is unavailable.

Calculation details
Average soil unit weight20 kN/m³
Slip-plane pore pressure u3.69 kPa
Static effective normal stress3.83 kPa
Static driving shear stress13.57 kPa
Seismic effective normal stress-3.63 kPa
Seismic driving shear stress17.71 kPa
Static F.S. minus 1.50-1.074
Seismic F.S. minus 1.10—

Inputs

Slope and shear strength
Water and seismic loading
0 is dry; 1 puts parallel seepage at the surface.

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

A nonpositive effective normal stress means this frictional contact model cannot return a seismic factor.

  1. Parallel seepage gives u = 3.688 kPa. The static effective normal and driving shear stresses are 3.833 kPa and 13.569 kPa.
  2. Divide c′ + σ′n tan φ′ by the driving shear stress to get a static F.S. of 0.426.
  3. The pseudo-static effective normal stress is -3.629 kPa. The contact model cannot return a seismic factor.
Static F.S.0.43Seismic F.S.—Dry F.S.0.65Pore ratio0.115
Original case inputs
Slope angle β61 °
Vertical plane depth z1.6 m
Cohesion c′3 kPa
Friction angle φ′36 °
Moist weight γ18 kN/m³
Saturated weight γsat20 kN/m³
Water height ratio m1
Seismic coefficient kh0.55

Method & assumptions

  1. Plane depth z is vertical. Average soil weight is γ(1 − m) + γsat m, where m is saturated height divided by z. Parallel seepage gives u = γw m z cos²β. The pore-pressure ratio is u divided by total vertical stress.
  2. Static F.S. = [c′ + (σv cos²β − u) tan φ′]/(σv sinβ cosβ). The dry reference uses the moist unit weight and u = 0.
  3. The horizontal down-slope inertial force subtracts kh σv sinβ cosβ from effective normal stress and adds kh σv cos²β to driving shear. Vertical acceleration and seismic pore-pressure generation are outside this model.
  4. The sample thresholds are 1.50 static and 1.10 pseudo-static. A nonpositive effective normal stress makes the frictional seismic screen unavailable. Use a different stability model for deep, circular or nonparallel failure.