Worked example
Seismic slope with loss of normal contact
A deliberately severe combination sets the phreatic line at grade and applies strong downslope acceleration.
Results
Edit inputs ↓- Static F.S.
- 0.43
- Seismic F.S.
- —
- Dry F.S.
- 0.65
- Pore ratio
- 0.115
- Slip plane
- Phreatic line
- Driving load
At least one applicable slope factor falls below the displayed screening limit. The seismic case loses effective normal contact. A frictional sliding factor is unavailable.
Calculation details
| Average soil unit weight | 20 kN/m³ |
|---|---|
| Slip-plane pore pressure u | 3.69 kPa |
| Static effective normal stress | 3.83 kPa |
| Static driving shear stress | 13.57 kPa |
| Seismic effective normal stress | -3.63 kPa |
| Seismic driving shear stress | 17.71 kPa |
| Static F.S. minus 1.50 | -1.074 |
| Seismic F.S. minus 1.10 | — |
GeotechSoilLab · Screening sheet · Metric SI
Seismic slope with loss of normal contact
| Slope angle β | 61 ° |
|---|---|
| Vertical plane depth z | 1.6 m |
| Cohesion c′ | 3 kPa |
| Friction angle φ′ | 36 ° |
| Moist weight γ | 18 kN/m³ |
| Saturated weight γsat | 20 kN/m³ |
| Water height ratio m | 1 |
| Seismic coefficient kh | 0.55 |
| Static F.S. | 0.43 |
|---|---|
| Seismic F.S. | — |
| Dry F.S. | 0.65 |
| Pore ratio | 0.115 |
| Average soil unit weight | 20 kN/m³ |
| Slip-plane pore pressure u | 3.69 kPa |
| Static effective normal stress | 3.83 kPa |
| Static driving shear stress | 13.57 kPa |
| Seismic effective normal stress | -3.63 kPa |
| Seismic driving shear stress | 17.71 kPa |
| Static F.S. minus 1.50 | -1.074 |
| Seismic F.S. minus 1.10 | — |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Worked result
A nonpositive effective normal stress means this frictional contact model cannot return a seismic factor.
- Parallel seepage gives u = 3.688 kPa. The static effective normal and driving shear stresses are 3.833 kPa and 13.569 kPa.
- Divide c′ + σ′n tan φ′ by the driving shear stress to get a static F.S. of 0.426.
- The pseudo-static effective normal stress is -3.629 kPa. The contact model cannot return a seismic factor.
Original case inputs
| Slope angle β | 61 ° |
|---|---|
| Vertical plane depth z | 1.6 m |
| Cohesion c′ | 3 kPa |
| Friction angle φ′ | 36 ° |
| Moist weight γ | 18 kN/m³ |
| Saturated weight γsat | 20 kN/m³ |
| Water height ratio m | 1 |
| Seismic coefficient kh | 0.55 |
Method & assumptions
- Plane depth z is vertical. Average soil weight is γ(1 − m) + γsat m, where m is saturated height divided by z. Parallel seepage gives u = γw m z cos²β. The pore-pressure ratio is u divided by total vertical stress.
- Static F.S. = [c′ + (σv cos²β − u) tan φ′]/(σv sinβ cosβ). The dry reference uses the moist unit weight and u = 0.
- The horizontal down-slope inertial force subtracts kh σv sinβ cosβ from effective normal stress and adds kh σv cos²β to driving shear. Vertical acceleration and seismic pore-pressure generation are outside this model.
- The sample thresholds are 1.50 static and 1.10 pseudo-static. A nonpositive effective normal stress makes the frictional seismic screen unavailable. Use a different stability model for deep, circular or nonparallel failure.
More worked examples
- Dry frictional soil slopeA dry granular slope has a shallow plane parallel to the ground surface.
- Slope saturated to the surfaceLong-duration seepage brings the phreatic line to the slope surface.
- Slope with a halfway phreatic lineGroundwater occupies the lower half of a thin residual-soil layer over bedrock.
- Pseudo-static slope with horizontal loadingA preliminary seismic screen applies a horizontal inertia coefficient on a shallow sliding layer.
- Steep slope below the static targetA steep saturated residual-soil slope has modest cohesion and a shallow planar slip surface.