Worked example

Gravel with a dual symbol (GP-GM)

A gravel-dominant specimen contains 8% low-plasticity silty fines.

USCS group
GP-GM
Plasticity PI
4 %
Liquidity LI
-0.25
Uniformity Cu
109.09
Casagrande plasticity chart Schematic
Casagrande plasticity chart, schematic Plasticity index (%)Fines ML65050100Sample GP-GMLiquid limit (%)U-line screenWithin envelope
  • A-line
  • U-line
  • Specimen

The measured limits plot within the U-line screening envelope.

Calculation details
Dominant fractionGravel-dominant
Fines groupML
GradationPoorly graded
Curvature coefficient Cc8.25
A-line ordinate at LL6.6 %
U-line ordinate at LL18.9 %
Gravel retained on No. 466 %
Sand between No. 4 and No. 20026 %

Inputs

Grain-size distribution
Atterberg limits

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

The curvature coefficient falls outside 1–3. The gradation and silty fines combine as GP-GM.

  1. 8% passes No. 200. The dominant fraction is gravel-dominant.
  2. Subtract PL = 25% from LL = 29% for PI = 4%. The A-line at this LL is 6.57%.
  3. Cu = 109.091 and Cc = 8.25. Applying the sieve and fines criteria gives GP-GM.
USCS groupGP-GMPlasticity PI4 %Liquidity LI-0.25Uniformity Cu109.09
Original case inputs
Passing No. 434 %
Passing No. 2008 %
Particle diameter D₁₀0.11 mm
Particle diameter D₃₀3.3 mm
Particle diameter D₆₀12 mm
Fines testMeasured limits
Liquid limit LL29 %
Plastic limit PL25 %
Natural water content24 %

Method & assumptions

  1. Use the portion passing 75 mm. At 50% or more passing No. 200 the soil is fine-grained. In coarse soil, gravel must exceed half the coarse fraction to control the symbol.
  2. With less than 5% fines, grade using Cu = D₆₀/D₁₀ and Cc = D₃₀²/(D₁₀D₆₀). Well-graded gravel requires Cu ≥ 4 and sand Cu ≥ 6. Both require 1 ≤ Cc ≤ 3. From 5% to 12% fines, assign a dual symbol. Enter percentile diameters from the same gradation curve as the passing percentages.
  3. PI = LL − PL and LI = (w − PL)/PI. The A-line is PI = 0.73(LL − 20). The low-LL CL-ML region is on or above the A-line with PI from 4 to 7. LL = 50 separates low and high liquid limits.
  4. The U-line uses PI = 0.9(LL − 8) and an LL = 16 lower segment. Points above or left of that envelope flag a test-data check. Use lab evidence to distinguish organic material and peat.