Worked example

Well-graded clean sand (SW)

Sieve results describe a clean sand with a broad particle-size range.

USCS group
SW
Plasticity PI
—
Liquidity LI
—
Uniformity Cu
7.81
Casagrande plasticity chart Schematic
Casagrande plasticity chart, schematic Plasticity index (%)Fines ML65050100NonplasticLiquid limit (%)U-line screenNo plotted point
  • A-line
  • U-line
  • Specimen

The fines are entered as nonplastic. Atterberg chart coordinates are unavailable.

Calculation details
Dominant fractionSand-dominant
Fines groupML
GradationWell graded
Curvature coefficient Cc1.152
A-line ordinate at LL—
U-line ordinate at LL—
Gravel retained on No. 48 %
Sand between No. 4 and No. 20089 %

Inputs

Grain-size distribution
Atterberg limits

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

There are less than 5% fines. The sand meets both the uniformity and curvature criteria for SW.

  1. 3% passes No. 200. The dominant fraction is sand-dominant.
  2. The fines are nonplastic.
  3. Cu = 7.813 and Cc = 1.152. Applying the sieve and fines criteria gives SW.
USCS groupSWPlasticity PI—Liquidity LI—Uniformity Cu7.81
Original case inputs
Passing No. 492 %
Passing No. 2003 %
Particle diameter D₁₀0.16 mm
Particle diameter D₃₀0.48 mm
Particle diameter D₆₀1.25 mm
Fines testNonplastic

Method & assumptions

  1. Use the portion passing 75 mm. At 50% or more passing No. 200 the soil is fine-grained. In coarse soil, gravel must exceed half the coarse fraction to control the symbol.
  2. With less than 5% fines, grade using Cu = D₆₀/D₁₀ and Cc = D₃₀²/(D₁₀D₆₀). Well-graded gravel requires Cu ≥ 4 and sand Cu ≥ 6. Both require 1 ≤ Cc ≤ 3. From 5% to 12% fines, assign a dual symbol. Enter percentile diameters from the same gradation curve as the passing percentages.
  3. PI = LL − PL and LI = (w − PL)/PI. The A-line is PI = 0.73(LL − 20). The low-LL CL-ML region is on or above the A-line with PI from 4 to 7. LL = 50 separates low and high liquid limits.
  4. The U-line uses PI = 0.9(LL − 8) and an LL = 16 lower segment. Points above or left of that envelope flag a test-data check. Use lab evidence to distinguish organic material and peat.

More worked examples