Worked example

-16 return hose at 28 GPM

The return path uses a lower velocity band than the pressure path. Compare the selected ID with the rounded-up nominal dash size.

Inputs

GPM
Selecting a grade loads its nominal 40 °C viscosity.
cSt
Replace the grade value with viscosity at the actual oil temperature.
Use actual hose or tube ID for a specific product.

Anatomy

Hose cross-section and service velocity
Hose cross-section and service velocityINSIDE DIA.1inOIL VELOCITY11.44ft/sREYNOLDS2767LOSS / LENGTH0.2664psi/ftOil pathNominal dash boreCross-sectionInside diameterPressureReturnTank / suctionOil velocity / service limit76.25%0%100% reference150%

Results

US customary

Transition-region friction is an estimate. Measure the pressure drop if it affects the design margin.

Selected inside diameter1in
Mean oil velocity11.438ft/s3.486m/s
Reynolds number2,767.237
Reynolds regimeTransitional
Darcy friction factor0.02929
Straight-line pressure loss0.2664psi/ft0.0603bar/m
Typical service minimum10ft/s
Typical service maximum15ft/s
Minimum ID at velocity limit0.8732in
Minimum nominal dash size-16

Worked calculation

  1. ID and velocity

    Nominal hose dash = ID in sixteenths of an inch. With measured ID D, v = 4Q/(πD²). Minimum ID = √[4Q/(πv_max)].

  2. Flow regime

    Re = vD/ν. Laminar below 2,300, transitional from 2,300 to 3,999, turbulent at 4,000 and above. Density ≈ 1,000 × SG kg/m³.

  3. Darcy–Weisbach

    ΔP/L = fρv²/(2D). Use f = 64/Re in laminar flow and the smooth-wall Haaland correlation in turbulent flow, with linear blending in transition.

Results for the original example inputs
Selected inside diameter1in
Mean oil velocity11.438ft/s
Reynolds number2,767.237
Reynolds regimeTransitional
Straight-line pressure loss0.2664psi/ft
Minimum nominal dash size-16

Uses nominal dash IDs and typical velocity bands. Fit checks require actual bore and OEM working-pressure ratings. The straight-run loss excludes fittings, roughness, bends and entrance losses.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.