Hydraulic Hose & Tube ID Sizing Calculator

Check oil velocity, flow regime and straight-run pressure loss for suction, return or pressure lines.

Inputs

GPM
Selecting a grade loads its nominal 40 °C viscosity.
cSt
Replace the grade value with viscosity at the actual oil temperature.
Use actual hose or tube ID for a specific product.

Anatomy

Hose cross-section and service velocity
Hose cross-section and service velocityINSIDE DIA.0.75inOIL VELOCITY13.07ft/sREYNOLDS1650LOSS / LENGTH0.6216psi/ftOil pathNominal dash boreCross-sectionInside diameterPressureReturnTank / suctionOil velocity / service limit52.29%0%100% reference150%

Results

US customary

Oil velocity is below the typical band for this service. Check routing, cold-start behavior and available hose sizes.

Selected inside diameter0.75in
Mean oil velocity13.072ft/s3.984m/s
Reynolds number1,650.029
Reynolds regimeLaminar
Darcy friction factor0.03879
Straight-line pressure loss0.6216psi/ft0.1406bar/m
Typical service minimum15ft/s
Typical service maximum25ft/s
Minimum ID at velocity limit0.5423in
Minimum nominal dash size-10

Formulas and assumptions

  1. ID and velocity

    Nominal hose dash = ID in sixteenths of an inch. With measured ID D, v = 4Q/(πD²). Minimum ID = √[4Q/(πv_max)].

  2. Flow regime

    Re = vD/ν. Laminar below 2,300, transitional from 2,300 to 3,999, turbulent at 4,000 and above. Density ≈ 1,000 × SG kg/m³.

  3. Darcy–Weisbach

    ΔP/L = fρv²/(2D). Use f = 64/Re in laminar flow and the smooth-wall Haaland correlation in turbulent flow, with linear blending in transition.

Uses nominal dash IDs and typical velocity bands. Fit checks require actual bore and OEM working-pressure ratings. The straight-run loss excludes fittings, roughness, bends and entrance losses.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.