Worked example

Motor at an intermittent pressure point

The 4,800 psi operating point illustrates high torque at moderate flow. Check the actual model’s intermittent duration and pressure rating.

Inputs

in³/rev
psi
Inlet pressure minus outlet pressure.
GPM
%
%
RPM
%
Percentage of running torque for this estimate. Use OEM breakaway data when available.

Anatomy

Motor torque versus differential pressure
Motor torque versus differential pressureSHAFT SPEED454.4RPMRUN TORQUE304.6lb-ftSTART TORQUE231.5lb-ftSHAFT POWER26.35HPOil motorShaftTorque384 lb-ftDifferential pressurePressureReturnTank / suctionShaft speed / entered rating60.59%0%100% reference150%

Results

US customary

Starting torque uses the entered estimate factor. Verify breakaway torque and allowable speed against the motor’s performance data.

Actual shaft speed454.448RPM
Theoretical shaft speed488.654RPM
Theoretical torque331.042lb-ft
Running torque304.559lb-ft412.926N·m
Estimated starting torque231.465lb-ft
Shaft output power26.352HP19.651kW
Hydraulic input power30.8HP
Overall efficiency85.56%

Worked calculation

  1. Shaft speed

    RPM = 60 × Q × η_v/D when Q is in m³/s and D is in m³/rev.

  2. Running and starting torque

    Ideal torque = ΔP × D/(2π). Running torque = ideal torque × η_m. Starting estimate = running torque × the entered start factor.

  3. Shaft power

    P = T × 2π × RPM/60. In US units, HP ≈ torque (lb-ft) × RPM/5252.

Results for the original example inputs
Theoretical shaft speed488.654RPM
Actual shaft speed454.448RPM
Theoretical torque331.042lb-ft
Running torque304.559lb-ft
Estimated starting torque231.465lb-ft
Shaft output power26.352HP

Steady-point estimate using constant efficiencies. Verify intermittent versus continuous pressure, minimum speed, breakaway torque and case-drain limits with the OEM.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.