Worked example

Winch motor starting-torque estimate

With the entered start factor at 68%, estimated breakaway torque is below running torque. Compare the estimate with the OEM starting curve.

Inputs

in³/rev
psi
Inlet pressure minus outlet pressure.
GPM
%
%
RPM
%
Percentage of running torque for this estimate. Use OEM breakaway data when available.

Anatomy

Motor torque versus differential pressure
Motor torque versus differential pressureSHAFT SPEED230.2RPMRUN TORQUE710.2lb-ftSTART TORQUE483lb-ftSHAFT POWER31.13HPOil motorShaftTorque1393 lb-ftDifferential pressurePressureReturnTank / suctionShaft speed / entered rating30.7%0%100% reference150%

Results

US customary

Starting torque uses the entered estimate factor. Verify breakaway torque and allowable speed against the motor’s performance data.

Actual shaft speed230.23RPM
Theoretical shaft speed253RPM
Theoretical torque835.563lb-ft
Running torque710.229lb-ft962.941N·m
Estimated starting torque482.956lb-ft
Shaft output power31.133HP23.216kW
Hydraulic input power40.25HP
Overall efficiency77.35%

Worked calculation

  1. Shaft speed

    RPM = 60 × Q × η_v/D when Q is in m³/s and D is in m³/rev.

  2. Running and starting torque

    Ideal torque = ΔP × D/(2π). Running torque = ideal torque × η_m. Starting estimate = running torque × the entered start factor.

  3. Shaft power

    P = T × 2π × RPM/60. In US units, HP ≈ torque (lb-ft) × RPM/5252.

Results for the original example inputs
Theoretical shaft speed253RPM
Actual shaft speed230.23RPM
Theoretical torque835.563lb-ft
Running torque710.229lb-ft
Estimated starting torque482.956lb-ft
Shaft output power31.133HP

Steady-point estimate using constant efficiencies. Verify intermittent versus continuous pressure, minimum speed, breakaway torque and case-drain limits with the OEM.