Worked example
Motor at an intermittent pressure point
The 4,800 psi operating point illustrates high torque at moderate flow. Check the actual model’s intermittent duration and pressure rating.
Inputs
Anatomy
Motor torque versus differential pressureResults
US customaryStarting torque uses the entered estimate factor. Verify breakaway torque and allowable speed against the motor’s performance data.
| Actual shaft speed | 454.448RPM |
|---|---|
| Theoretical shaft speed | 488.654RPM |
| Theoretical torque | 331.042lb-ft |
| Running torque | 304.559lb-ft412.926N·m |
| Estimated starting torque | 231.465lb-ft |
| Shaft output power | 26.352HP19.651kW |
| Hydraulic input power | 30.8HP |
| Overall efficiency | 85.56% |
Worked calculation
Shaft speed
RPM = 60 × Q × η_v/D when Q is in m³/s and D is in m³/rev.
Running and starting torque
Ideal torque = ΔP × D/(2π). Running torque = ideal torque × η_m. Starting estimate = running torque × the entered start factor.
Shaft power
P = T × 2π × RPM/60. In US units, HP ≈ torque (lb-ft) × RPM/5252.
| Theoretical shaft speed | 488.654RPM |
|---|---|
| Actual shaft speed | 454.448RPM |
| Theoretical torque | 331.042lb-ft |
| Running torque | 304.559lb-ft |
| Estimated starting torque | 231.465lb-ft |
| Shaft output power | 26.352HP |
Steady-point estimate using constant efficiencies. Verify intermittent versus continuous pressure, minimum speed, breakaway torque and case-drain limits with the OEM.
The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.