Worked example

Air cooler in a hot shop

With 115 °F ambient air, available oil-to-air temperature difference is small. Both the tank and air cooler reject less heat per unit area.

Inputs

HP
%
Useful power divided by shaft input over the duty cycle.
GPM
°F
°F
ft²
BTU/hr·ft²·°F
Typical bare-steel starting estimate is 2–2.5 BTU/hr·ft²·°F.
°F
Oil inlet temperature minus coolant inlet temperature at the cooler.

Anatomy

Hydraulic power unit thermal balance
Hydraulic power unit thermal balanceCIRCUIT HEAT30.5kBTU/hrTANK HEAT1980BTU/hrCOOLER LOAD28.6kBTU/hrMIN. TANK84galPumpLoadCoolerReservoirTank heatPressureReturnTank / suctionCooler load / circuit heat93.52%0%100% reference150%

Results

US customary
Circuit heat generation30,533.203BTU/hr8.948kW
Oil target minus ambient25°F
Passive tank rejection1,980BTU/hr0.58kW
Required cooler heat removal28,553.203BTU/hr8.368kW
Net heat · horsepower equivalent11.222HP8.368kW
Cooler rating at entered ETD1,142.1281BTU/hr/°F0.6025kW/°C
Reservoir guide · 3 min84gal
Reservoir guide · 5 min140gal

Worked calculation

  1. Heat generation

    Heat in = shaft input × (1 − duty-weighted efficiency). Use average shaft power across the same duty cycle.

  2. Reservoir heat rejection

    Tank heat out = h × exposed area × (T_oil − T_ambient). A negative result means the surroundings add heat.

  3. Cooler capacity and reservoir volume

    Cooler load = max(0, heat in − tank heat out). Required cooler rating = load/ETD. The 3–5 minute volume guide is 3–5 gal per GPM or 3–5 L per LPM.

Results for the original example inputs
Circuit heat generation30,533.203BTU/hr
Passive tank rejection1,980BTU/hr
Required cooler heat removal28,553.203BTU/hr
Cooler rating at entered ETD1,142.1281BTU/hr/°F
Reservoir guide · 3 min84gal
Reservoir guide · 5 min140gal

Steady thermal balance at the entered target oil temperature. OEM cooler ratings depend on oil viscosity, coolant and oil flow, fan airflow, fouling and allowable pressure drop. Size tank working volume for deaeration, return levels and cylinder drawdown.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.