Hydraulic Reservoir & Oil Cooler Sizing Calculator
Balance circuit heat, passive tank rejection and the cooler duty required to hold the oil below its target temperature.
Inputs
Anatomy
Hydraulic power unit thermal balanceResults
US customary| Circuit heat generation | 16,793.262BTU/hr4.922kW |
|---|---|
| Oil target minus ambient | 55°F |
| Passive tank rejection | 3,217.5BTU/hr0.943kW |
| Required cooler heat removal | 13,575.762BTU/hr3.979kW |
| Net heat · horsepower equivalent | 5.335HP3.979kW |
| Cooler rating at entered ETD | 271.5152BTU/hr/°F0.1432kW/°C |
| Reservoir guide · 3 min | 48gal |
| Reservoir guide · 5 min | 80gal |
Formulas and assumptions
Heat generation
Heat in = shaft input × (1 − duty-weighted efficiency). Use average shaft power across the same duty cycle.
Reservoir heat rejection
Tank heat out = h × exposed area × (T_oil − T_ambient). A negative result means the surroundings add heat.
Cooler capacity and reservoir volume
Cooler load = max(0, heat in − tank heat out). Required cooler rating = load/ETD. The 3–5 minute volume guide is 3–5 gal per GPM or 3–5 L per LPM.
Steady thermal balance at the entered target oil temperature. OEM cooler ratings depend on oil viscosity, coolant and oil flow, fan airflow, fouling and allowable pressure drop. Size tank working volume for deaeration, return levels and cylinder drawdown.
The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.