Worked example

Higher effective discharge coefficient

At the same diameter and ΔP, a higher Cd increases modeled flow and throttling power in direct proportion.

Inputs

in
psi
A typical sharp-edged sizing range is 0.61–0.82.
Many mineral hydraulic oils are around 0.85–0.88.
psi
Enter the project’s differential-pressure check value.

Anatomy

Restriction and oil flow versus pressure drop
Restriction and oil flow versus pressure dropOIL FLOW14.17GPMPRESS. DROP800psiORIFICE ID0.14inVALVE LOSS6.615HPOrifice plateUpstreamDownstreamFlow rate19.41 GPMPressure dropPressureReturnTank / suctionPressure drop / review limit53.33%0%100% reference150%

Results

US customary
Orifice flow rate14.174GPM53.655LPM
Pressure drop ΔP800psi55.158bar
Equivalent orifice diameter0.14in
Mean orifice velocity295.411ft/s90.041m/s
Throttling power loss6.615HP4.932kW
Equivalent oil heat16,830.278BTU/hr

Worked calculation

  1. Turbulent orifice flow

    Q_gpm = 29.81 × Cd × d_in² × √(ΔP_psi/SG). Q_lpm ≈ 0.6661 × Cd × d_mm² × √(ΔP_bar/SG). The SI factor is converted from the same US expression.

  2. Solving for size or drop

    ΔP = SG × [Q/(K × Cd × d²)]². d = √[Q/(K × Cd × √(ΔP/SG))]. Use the matching unit-system constant K.

  3. Jet velocity and heat

    Mean velocity = Q/(πd²/4). Throttling loss = ΔP × Q. Under steady dissipation this loss becomes heat.

Results for the original example inputs
Equivalent orifice diameter0.14in
Pressure drop ΔP800psi
Orifice flow rate14.174GPM
Mean orifice velocity295.411ft/s
Throttling power loss6.615HP

Models a steady incompressible, turbulent sharp-edged restriction with a fixed discharge coefficient. Use valve OEM flow curves and check cavitation, jet erosion and minimum downstream pressure.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.