Worked example
High pressure loss through a small opening
An 0.09-inch opening at 9 GPM asks for a large differential. Compare it with the entered review threshold and check cavitation separately.
Inputs
Anatomy
Restriction and oil flow versus pressure dropResults
US customaryPressure drop exceeds the entered review threshold. Check downstream absolute pressure, cavitation and the valve’s differential rating.
| Orifice flow rate | 9GPM34.069LPM |
|---|---|
| Pressure drop ΔP | 3,180.463psi219.285bar |
| Equivalent orifice diameter | 0.09in |
| Mean orifice velocity | 453.886ft/s138.345m/s |
| Throttling power loss | 16.697HP12.451kW |
| Equivalent oil heat | 42,485.501BTU/hr |
Worked calculation
Turbulent orifice flow
Q_gpm = 29.81 × Cd × d_in² × √(ΔP_psi/SG). Q_lpm ≈ 0.6661 × Cd × d_mm² × √(ΔP_bar/SG). The SI factor is converted from the same US expression.
Solving for size or drop
ΔP = SG × [Q/(K × Cd × d²)]². d = √[Q/(K × Cd × √(ΔP/SG))]. Use the matching unit-system constant K.
Jet velocity and heat
Mean velocity = Q/(πd²/4). Throttling loss = ΔP × Q. Under steady dissipation this loss becomes heat.
| Equivalent orifice diameter | 0.09in |
|---|---|
| Pressure drop ΔP | 3,180.463psi |
| Orifice flow rate | 9GPM |
| Mean orifice velocity | 453.886ft/s |
| Throttling power loss | 16.697HP |
Models a steady incompressible, turbulent sharp-edged restriction with a fixed discharge coefficient. Use valve OEM flow curves and check cavitation, jet erosion and minimum downstream pressure.
The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.