Worked example
Higher effective discharge coefficient
At the same diameter and ΔP, a higher Cd increases modeled flow and throttling power in direct proportion.
Inputs
Anatomy
Restriction and oil flow versus pressure dropResults
US customary| Orifice flow rate | 14.174GPM53.655LPM |
|---|---|
| Pressure drop ΔP | 800psi55.158bar |
| Equivalent orifice diameter | 0.14in |
| Mean orifice velocity | 295.411ft/s90.041m/s |
| Throttling power loss | 6.615HP4.932kW |
| Equivalent oil heat | 16,830.278BTU/hr |
Worked calculation
Turbulent orifice flow
Q_gpm = 29.81 × Cd × d_in² × √(ΔP_psi/SG). Q_lpm ≈ 0.6661 × Cd × d_mm² × √(ΔP_bar/SG). The SI factor is converted from the same US expression.
Solving for size or drop
ΔP = SG × [Q/(K × Cd × d²)]². d = √[Q/(K × Cd × √(ΔP/SG))]. Use the matching unit-system constant K.
Jet velocity and heat
Mean velocity = Q/(πd²/4). Throttling loss = ΔP × Q. Under steady dissipation this loss becomes heat.
| Equivalent orifice diameter | 0.14in |
|---|---|
| Pressure drop ΔP | 800psi |
| Orifice flow rate | 14.174GPM |
| Mean orifice velocity | 295.411ft/s |
| Throttling power loss | 6.615HP |
Models a steady incompressible, turbulent sharp-edged restriction with a fixed discharge coefficient. Use valve OEM flow curves and check cavitation, jet erosion and minimum downstream pressure.
The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.