Hydraulic Pressure Intensifier & Relief-Valve Temperature Calculator

Estimate pressure multiplication and reduced flow, then check single-pass oil temperature rise across a relief valve.

Inputs

:1
psi
GPM
psi
psi
Use the actual differential across the relief valve.
lb/ft³
BTU/lb·°F
°F
°F

Anatomy

Area-ratio intensifier and relief temperature rise
Area-ratio intensifier and relief temperature riseBOOST PRESS.4500psiOUTLET FLOW4GPMOIL TEMP RISE17.78°FSEAL MARGIN24.22°FInlet pistonBoosted oilRelief valveOil warmingReturnPressureReturnTank / suctionBoost pressure / entered rating90%0%100% reference150%

Results

US customary
Ideal boosted pressure4,500psi310.264bar
Ideal high-side flow4GPM15.142LPM
Ideal transmitted power10.5HP
Calculated single-pass rise17.78°F9.878°C
Field estimate · ΔP/15016°F8.889°C
Oil temperature after relief135.78°F
Temperature below seal limit24.22°F

Formulas and assumptions

  1. Pressure multiplication

    R = A_low/A_high. Ideal pressure out = R × pressure in. Ideal flow out = flow in/R. Pressure × flow is conserved in this model.

  2. Single-pass heat balance

    ΔT = ΔP/(ρ × c_p) with Pa, kg/m³ and J/kg·K. Add the resulting temperature difference to the inlet temperature.

  3. Field approximation

    ΔT (°F) ≈ ΔP (psi)/150. Compare to the calculation using the entered oil properties and check the seal limit at the predicted outlet temperature.

Uses ideal same-stroke area multiplication and negligible inlet backpressure on the intensifier’s return side. Real output depends on leakage and refill duty. The relief model treats lost pressure energy as sensible heat in a single oil pass.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.