Hydraulic Pressure Intensifier & Relief-Valve Temperature Calculator
Estimate pressure multiplication and reduced flow, then check single-pass oil temperature rise across a relief valve.
Inputs
Anatomy
Area-ratio intensifier and relief temperature riseResults
US customary| Ideal boosted pressure | 4,500psi310.264bar |
|---|---|
| Ideal high-side flow | 4GPM15.142LPM |
| Ideal transmitted power | 10.5HP |
| Calculated single-pass rise | 17.78°F9.878°C |
| Field estimate · ΔP/150 | 16°F8.889°C |
| Oil temperature after relief | 135.78°F |
| Temperature below seal limit | 24.22°F |
Formulas and assumptions
Pressure multiplication
R = A_low/A_high. Ideal pressure out = R × pressure in. Ideal flow out = flow in/R. Pressure × flow is conserved in this model.
Single-pass heat balance
ΔT = ΔP/(ρ × c_p) with Pa, kg/m³ and J/kg·K. Add the resulting temperature difference to the inlet temperature.
Field approximation
ΔT (°F) ≈ ΔP (psi)/150. Compare to the calculation using the entered oil properties and check the seal limit at the predicted outlet temperature.
Uses ideal same-stroke area multiplication and negligible inlet backpressure on the intensifier’s return side. Real output depends on leakage and refill duty. The relief model treats lost pressure energy as sensible heat in a single oil pass.
The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.