Worked example

Single pass across a 5,000 psi relief

A full pressure drop at the relief valve creates a large instantaneous rise. Use the computed outlet temperature to evaluate thermal headroom.

Inputs

:1
psi
GPM
psi
psi
Use the actual differential across the relief valve.
lb/ft³
BTU/lb·°F
°F
°F

Anatomy

Area-ratio intensifier and relief temperature rise
Area-ratio intensifier and relief temperature riseBOOST PRESS.5000psiOUTLET FLOW7GPMOIL TEMP RISE39.68°FSEAL MARGIN-11.68°FInlet pistonBoosted oilRelief valveOil warmingReturnPressureReturnTank / suctionBoost pressure / entered rating90.91%0%100% reference150%

Results

US customary

Post-drop oil meets or exceeds the entered seal temperature limit. Elevated temperature can degrade seals and shorten oil life.

Ideal boosted pressure5,000psi344.738bar
Ideal high-side flow7GPM26.498LPM
Ideal transmitted power20.417HP
Calculated single-pass rise39.676°F22.042°C
Field estimate · ΔP/15033.333°F18.519°C
Oil temperature after relief171.676°F
Temperature below seal limit-11.676°F

Worked calculation

  1. Pressure multiplication

    R = A_low/A_high. Ideal pressure out = R × pressure in. Ideal flow out = flow in/R. Pressure × flow is conserved in this model.

  2. Single-pass heat balance

    ΔT = ΔP/(ρ × c_p) with Pa, kg/m³ and J/kg·K. Add the resulting temperature difference to the inlet temperature.

  3. Field approximation

    ΔT (°F) ≈ ΔP (psi)/150. Compare to the calculation using the entered oil properties and check the seal limit at the predicted outlet temperature.

Results for the original example inputs
Ideal boosted pressure5,000psi
Ideal high-side flow7GPM
Calculated single-pass rise39.676°F
Field estimate · ΔP/15033.333°F
Oil temperature after relief171.676°F
Temperature below seal limit-11.676°F

Uses ideal same-stroke area multiplication and negligible inlet backpressure on the intensifier’s return side. Real output depends on leakage and refill duty. The relief model treats lost pressure energy as sensible heat in a single oil pass.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.